Radiation Safety Regulation 2010


Queensland Crest
Radiation Safety Regulation 2010

Part 1 Preliminary

1Short title

This regulation may be cited as the Radiation Safety Regulation 2010.

2Commencement

Sections 7(2) and (3), 13(1)(j), 28, 33 and 65(1)(b) and (3) commence on 1 June 2011.

3Dictionary

The dictionary in schedule 9 defines particular words used in this regulation.

Part 2 Radiation sources and sealed source apparatus

Division 1 Radioactive substances

4Concentration or activity of a radionuclide—Act, sch 2, definition radioactive substance

For the Act, schedule 2, definition radioactive substance, paragraph (a), radioactive material containing a radionuclide stated in schedule 1, column 1 is a radioactive substance if—
(a)the concentration of the radionuclide is equal to, or more than, the concentration stated in schedule 1, column 2 shown opposite the radionuclide; and
(b)the activity of the radionuclide is equal to, or more than, the activity stated in schedule 1, column 3 shown opposite the radionuclide.

5Concentration of a radionuclide in a mineral substance—Act, sch 2, definition radioactive substance

(1)This section applies to the following substances (the mineral substances)—
(a)a mineral situated outside the boundaries of land the subject of a mining lease, mineral development licence or exploration permit within the meaning of the Mineral Resources Act 1989;
(b)a substance into which a mineral has been changed as a result of the processing of the mineral.

Examples of the processing of a mineral—

the refining, smelting or calcining of a mineral
(2)Despite section 4, for the Act, schedule 2, definition radioactive substance, paragraph (a), a mineral substance containing a radionuclide stated in schedule 1, column 1 is a radioactive substance if the concentration of the radionuclide is equal to, or more than, the amount worked out by multiplying the concentration stated in schedule 1, column 2 shown opposite the radionuclide by 10.

Division 2 Radiation apparatus

6Apparatus emitting ionising radiation—Act, sch 2, definition radiation apparatus

(1)For the Act, schedule 2, definition radiation apparatus, paragraphs (a) and (b), the amount is 1 microgray per hour, measured at a distance of 10cm from any accessible surface of the apparatus.
(2)In this section—
accessible surface, of an apparatus, means a surface of the apparatus that may easily be touched.

7Apparatus emitting non-ionising radiation—Act, sch 2, definition radiation apparatus

(1)For the Act, schedule 2, definition radiation apparatus, paragraphs (c) and (d)—
(a)a laser that could reasonably be used to carry out a diagnostic, therapeutic or cosmetic procedure involving the irradiation of a person is a radiation apparatus; and
(b)the amount for the laser is the accessible emission limit, for a class 3B laser for the period, stated in, and measured in accordance with, the laser standard.
(2)For the Act, schedule 2, definition radiation apparatus, paragraphs (c) and (d)—
(a)a relevant solarium is a radiation apparatus; and
(b)the amount for the solarium is an erythemally effective dose of 100 joules per square metre per hour.
(3)In this section—
CIE standard means the document called ‘Erythema reference action spectrum and standard erythema dose. CIE S 007/E-1998. Vienna: Commission Internationale de l’Eclairage 1998’.
erythemally effective dose means the dose obtained by weighting the spectral distribution of electromagnetic radiation incident on the measured area with the erythemal effectiveness stated in the CIE standard across the electromagnetic radiation wavelength range of 280nm to 400nm and then integrating to obtain the total dose in joules per square metre in accordance with the CIE standard.

Division 3 Security enhanced source

8What is a security enhanced source

(1)This section prescribes what is a security enhanced source for the Act, schedule 2, definition security enhanced source.
(2)A sealed radioactive substance or aggregation of sealed radioactive substances is a security enhanced source if it is classified as security category 1, 2 or 3 under schedule 2, part 1 according to its activity ratio.
(3)For subsection (2), the activity ratio of a sealed radioactive substance is worked out by the formula—

equation

      where—
A means the activity of the radionuclide in the sealed radioactive substance, stated in gigabecquerels.
RAV means the activity value stated in schedule 2, part 2 for the radionuclide in the sealed radioactive substance.
(4)For subsection (2), the activity ratio of an aggregation of 2 or more sealed radioactive substances is the sum of the activity ratios of the sealed radioactive substances in the aggregation worked out under subsection (3).

Division 4 Certificates of compliance

9Periods within which certificates of compliance must be obtained—Act, s 18(2)

(1)For the Act, section 18(2), the period is—
(a)for an ionising radiation source, or a sealed radioactive substance incorporated in a sealed source apparatus, used to carry out a diagnostic or therapeutic procedure involving the irradiation of a person, other than an ionising radiation apparatus used to carry out intra-oral dental diagnostic radiography or plain film diagnostic radiography—1 year; or
(b)for an ionising radiation apparatus used to carry out intra-oral dental diagnostic radiography or plain film diagnostic radiography involving the irradiation of a person—3 years; or
(c)for an ionising radiation source, or a sealed radioactive substance incorporated in a sealed source apparatus, used to carry out a radiation practice for a research project—1 year; or
(d)for an ionising radiation source, or a sealed radioactive substance incorporated in a sealed source apparatus, used during a person’s study or training at an educational institution—1 year; or
(e)for an ionising radiation source, or a sealed radioactive substance incorporated in a sealed source apparatus, used to carry out a radiation practice, other than a radiation practice stated in paragraph (a), (b), (c) or (d)—3 years; or
(f)for a laser apparatus used to carry out a diagnostic, therapeutic or cosmetic procedure involving the irradiation of a person—1 year.
(2)For the Act, section 18(4) and (5), the period is 5 years.

Part 3 Act instruments

Division 1 General

pt 3 div 1 hdg ins 2019 SL No. 117 s 17

10Documents relating to proof of identity—Act, s 51

(1)This section prescribes, for the Act, section 51(1)(c)(ii) and (iii), the documents to prove an applicant’s or nominated person’s identity.
(2)A relevant application must be accompanied by—
(a)a copy of 1 document mentioned in schedule 4, part 1; and
(b)a copy of 1 document mentioned in schedule 4, part 2.
(3)At least 1 of the documents must contain a photograph of the applicant or nominated person.
(4)In this section—
copy, of a document, means a reproduction of the document in the form required or permitted by the approved form for the relevant application.
relevant application means any of the following—
(a)an application for a possession licence;
(b)an application for a use licence;
(c)an application for a transport licence.

s 10 amd 2012 SL No. 246 s 4; 2019 SL No. 40 s 16

11Notification of change of circumstances—Act, s 92(2)

For the Act, section 92(2), the changes in the holder’s circumstances are the following—
(a)for a holder of a licence, a change in any of the following—
(i)if the licence holder is not a prescribed licensee—the licence holder’s name;
(ii)if the licence is a use licence and the licence holder is a health practitioner or a veterinary surgeon—
(A)the licence holder’s accreditation, enrolment or registration as a health practitioner or a veterinary surgeon; or
(B)a condition attaching to the accreditation, enrolment or registration;
(b)for a holder of an accreditation certificate, a change in either of the following—
(i)the certificate holder’s name;
(ii)the certificate holder’s contact details;

Examples of contact details—

address, telephone number, facsimile number, email address
(c)for the holder of a continuing approval to acquire, a change in the approval holder’s name;
(d)for the holder of a radiation safety officer certificate, a change in the certificate holder’s name.

s 11 amd 2019 SL No. 117 s 18

12Prescribed sealed radioactive substance—Act, s 52(1)

(1)For the Act, section 52(1)(b), an iodine-125 seed with an activity of no more than 40MBq is a prescribed sealed radioactive substance for brachytherapy.
(2)In this section—
iodine-125 seed means iodine-125 as a sealed radioactive substance.

13Certain possession, use or transport licences—Act, s 75(3) and (4)

(1)For the Act, section 75(3)—
(a)a possession licence to possess or a use licence to use an ionising radiation source for intra-oral dental diagnostic radiography, involving the irradiation of a person, is subject to the condition that the holder of the licence comply with the ‘Code of Practice for Radiation Protection in Dentistry (2005)’ published by ARPANSA; and
(b)a possession licence to possess or a use licence to use an ionising radiation source for conducting health-related research on persons is subject to the condition that the holder of the licence comply with the ‘Code of Practice for the Exposure of Humans to Ionizing Radiation for Research Purposes (2005)’ published by ARPANSA; and
(c)a possession licence to possess or a use licence to use a sealed source apparatus for density-gauging or moisture-gauging for geo-technical purposes is subject to the condition that the holder of the licence comply with the ‘Code of Practice for Portable Density/Moisture Gauges Containing Radioactive Sources (2004)’ published by ARPANSA; and
(d)a possession licence to possess or a use licence to use a radioactive substance to carry out a diagnostic or therapeutic procedure involving irradiation of a person is subject to the condition that the holder of the licence comply with the document called ‘Recommendations for the Discharge of Patients Undergoing Treatment with Radioactive Substances (2002)’ published by ARPANSA; and
(e)a possession licence to possess or a use licence to use an ionising radiation source to carry out a diagnostic or therapeutic procedure involving the irradiation of a person is subject to the condition that the holder of the licence comply with the ‘Code of Practice for Radiation Protection in the Medical Applications of Ionizing Radiation (2008)’ published by ARPANSA; and
(f)a possession licence to possess or a use licence to use an ionising radiation source for industrial gauging is subject to the condition that the holder of the licence comply with the ‘Code of Practice for Safe Use of Fixed Radiation Gauges (2007)’ published by ARPANSA; and
(g)a possession licence to possess or a use licence to use a radiation source that is a security enhanced source is subject to the condition that the holder of the licence comply with the ‘Code of Practice for the Security of Radioactive Sources (2007)’ published by ARPANSA; and
(h)a possession licence to possess or a use licence to use an ionising radiation source to carry out a diagnostic or therapeutic procedure involving irradiation of an animal is subject to the condition that the holder of the licence comply with the ‘Code of Practice for Radiation Protection in Veterinary Medicine (2009)’ published by ARPANSA; and
(i)a possession licence to possess or a use licence to use an ionising radiation source to carry out a diagnostic procedure involving the irradiation of a person by a chiropractor is subject to the condition that the holder of the licence comply with the ‘Code of Practice for Radiation Protection in the Application of Ionizing Radiation by Chiropractors (2009)’ published by ARPANSA.

Editor’s notes—

1Copies of the codes or documents mentioned in paragraphs (a) to (i) are available on ARPANSA’s website.
2Copies of the codes or documents mentioned in paragraphs (a) to (i) may be bought from ARPANSA at 619 Lower Plenty Road, Yallambie, Victoria 3085.
(2)For the Act, section 75(4)—
(a)a transport licence is subject to the condition that the holder of the licence comply with the transport code of practice; and
(b)a transport licence to transport a radiation source that is a security enhanced source is subject to the condition that the holder of the licence comply with the ‘Code of Practice for the Security of Radioactive Sources (2007)’ published by ARPANSA.

Editor’s notes—

1Copies of the codes mentioned in paragraphs (a) and (b) are available on ARPANSA’s website.
2Copies of the codes mentioned in paragraphs (a) and (b) may be bought from ARPANSA at 619 Lower Plenty Road, Yallambie, Victoria 3085.

s 13 (1)(j) exp 30 December 2014 (see s 94A)

14Relevant offences

For the Act, schedule 2, definition relevant offence, each of the following offences is prescribed—
(a)an offence mentioned in the Criminal Code Act 1995 (Cwlth), chapter 5;
(b)an offence mentioned in the Crimes Act 1914 (Cwlth), part II;
(c)an offence under a State law corresponding to an offence mentioned in the Crimes Act 1914 (Cwlth), part II;
(d)an offence under the Weapons of Mass Destruction (Prevention of Proliferation) Act 1995 (Cwlth), section 9;
(e)an offence under the Customs Act 1901 (Cwlth) relating to the importation or exportation of radioactive material;
(f)an identity-related offence including an offence related to—
(i)assuming another person’s identity; or
(ii)counterfeiting documents related to a person’s identity; or
(iii)falsifying documents related to a person’s identity;
(g)an offence related to the hijacking or destruction of an aircraft or sea vessel;
(h)an offence involving weapons or explosives including an offence related to possession, supply, production, importation, exportation or unlicensed use;
(i)an offence involving prohibited drugs including an offence related to—
(i)possession, if the maximum penalty prescribed is more than 2 years imprisonment; or
(ii)possession of equipment for the manufacture of a prohibited drug; or
(iii)supply, production, importation or exportation;
(j)an offence involving the production, importation or exportation of firearms.

Division 2 Prescribed licensees

pt 3 div 2 hdg ins 2019 SL No. 117 s 19

14AUse licensee—Act, s 103K

(1)For section 103K(1)(a) of the Act, a person is taken to hold a use licence if the person is registered under the Health Practitioner Regulation National Law to practice in the dental profession as a dentist, other than as a student.
(2)The radiation source the person is allowed to use is an intra-oral dental radiation apparatus.
(3)The radiation practice the person is allowed to carry out is intra-oral dental plain radiography.
(4)It is a condition of the licence that the person uses the radiation source in compliance with the ‘Code of Practice for Radiation Protection in Dentistry (2005)’ published by ARPANSA.

Editor’s note—

A copy of the code mentioned in subsection (4) is available on ARPANSA’s website.

s 14A ins 2019 SL No. 117 s 19

14BTransport licensee—Act, s 103K

(1)For section 103K(1)(b) of the Act, a person is taken to hold a transport licence if the person holds an authority under a corresponding transport law to transport a radioactive substance.
(2)The person may transport the radioactive substance into Queensland.
(3)It is a condition of the licence that the person transports the radioactive substance in compliance with the ‘Code of Practice for the Security of Radioactive Sources (2019)’ published by ARPANSA.

Editor’s note—

A copy of the code mentioned in subsection (3) is available on ARPANSA’s website.
(4)In this section—
authority includes an accreditation, approval, certification or licence.
corresponding transport law means a law of another State or the Commonwealth relating to the transportation of radioactive substances.

s 14B ins 2019 SL No. 117 s 19

Part 4 Disposal

Division 1 Disposal of radioactive material

15Disposal of radioactive material into the air or water, other than into the sewerage system—Act, s 26(1)(a)

(1)For the Act, section 26(1)(a)—
(a)for radioactive material, containing only 1 of the radionuclides stated in schedule 3, column 1, being disposed of into the air—the maximum concentration is the concentration stated in schedule 3, column 2 shown opposite the radionuclide; or
(b)for radioactive material, containing only 1 of the radionuclides stated in schedule 3, column 1, being disposed of into water—the maximum concentration is the concentration stated in schedule 3, column 3 shown opposite the radionuclide; or
(c)for radioactive material, containing more than 1 of the radionuclides stated in schedule 3, column 1, being disposed of into the air or water—the material’s disposal factor must be not more than 1.
(2)Subsection (1) does not apply to the disposal of radioactive material into the sewerage system.
(3)In this section—
disposal factor, for radioactive material containing more than 1 of the radionuclides stated in schedule 3, column 1, means the total of the amounts worked out by applying the formula to each of the radionuclides—

equation

where—
C, for a radionuclide, means the radionuclide’s concentration, measured in Bq per cubic metre.
MC, for a radionuclide, means—
(a)if the material is to be disposed of into the air—the concentration stated in schedule 3, column 2 shown opposite the radionuclide; or
(b)if the material is to be disposed of into water—the concentration stated in schedule 3, column 3 shown opposite the radionuclide.

16Disposal of radioactive material into the sewerage system—Act, s 26(1)(a)

(1)For the Act, section 26(1)(a)—
(a)for radioactive material, containing only 1 of the radionuclides stated in schedule 3, column 1, being disposed of into the sewerage system—the maximum concentration is the concentration stated in schedule 3, column 4 shown opposite the radionuclide; or
(b)for radioactive material, containing more than 1 of the radionuclides stated in schedule 3, column 1, being disposed of into the sewerage system—the material’s disposal factor must be not more than 1.
(2)For subsection (1), the point of disposal at which the concentration of a radionuclide in radioactive material is to be decided is a point at, or before, which the sewerage pipe leading from premises, at which the material is being disposed of, joins the main reticulation line of the sewerage system.
(3)In this section—
disposal factor, for radioactive material containing more than 1 of the radionuclides stated in schedule 3, column 1, means the total of the amounts worked out by applying the formula to each of the radionuclides—

equation

where—
C, for a radionuclide, means the radionuclide’s concentration, measured in Bq per cubic metre.
MC, for a radionuclide, means the concentration stated in schedule 3, column 4 shown opposite the radionuclide.

17Disposal of radioactive material, other than into the air, water or sewerage system—Act, s 26(1)(a)

(1)For the Act, section 26(1)(a)—
(a)for radioactive material, containing only 1 of the radionuclides stated in schedule 1, column 1, being disposed of other than into the air, water or sewerage system—the maximum concentration is one-half of the concentration stated in schedule 1, column 2 shown opposite the radionuclide; or
(b)for radioactive material, containing more than 1 of the radionuclides stated in schedule 1, column 1, being disposed of other than into the air, water or sewerage system—the material’s disposal factor must be not more than 1.
(2)In this section—
disposal factor, for radioactive material containing more than 1 of the radionuclides stated in schedule 1, means the total of the amounts worked out by applying the formula to each of the radionuclides—

equation

where—
C, for a radionuclide, means the radionuclide’s concentration, measured in Bq per gram.
MC, for a radionuclide, means one-half of the concentration stated in schedule 1, column 2 shown opposite the radionuclide.

Division 2 Requirements for disposal of certain apparatus or containers

18Removal etc. of radiation warning signs

(1)This section applies to a person disposing of—
(a)a container that has been used for the transport or storage of radioactive material; or
(b)an apparatus that once contained a sealed radioactive substance; or
(c)a radiation apparatus.
(2)The person must, immediately before the disposal, remove or make illegible all radiation warning signs attached to the container or apparatus.

Maximum penalty—20 penalty units.

(3)In this section—
radiation warning signs, attached to a container or apparatus, means labels adhering to, or symbols embedded in, the container or apparatus indicating that the container or apparatus poses a radiation hazard.

Part 5 Radiation safety and protection plans

Division 1 Radiation safety and protection measures for all radiation practices

19Methods and procedures—Act, s 28(6)

(1)For the Act, section 28(6), the following are radiation safety and protection measures for the carrying out of a radiation practice—
(a)safe handling procedures to be followed for the source;
(b)procedures and methods for ensuring the safe use of the source in the carrying out of the practice;
(c)if the practice involves the production of images—procedures and methods for ensuring the correct use of ancillary imaging equipment used in connection with the use of the source to carry out the practice;
(d)quality control procedures to be undertaken for—
(i)the source; and
(ii)if the source is a sealed radioactive substance incorporated in a sealed source apparatus—the apparatus; and
(iii)if the practice involves the production of images—any ancillary imaging equipment used in connection with the use of the source to carry out the practice;
(e)remediation procedures to be followed for an accident that could reasonably be expected to happen in relation to the carrying out of the practice.
(2)In this section—
remediation procedures, for an accident, means procedures designed to minimise a radiation hazard arising from the accident.

20Control of access to, or use of, radiation sources—Act, s 28(6)

For the Act, section 28(6), a radiation safety and protection measure for the carrying out of a radiation practice is a statement about how access to, or use of, the source is to be controlled.

21Supply of safety devices—Act, s 28(6)

(1)For the Act, section 28(6), the following are radiation safety and protection measures for the carrying out of a radiation practice—
(a)a requirement that the possession licensee in possession of the source, under the licence, for the practice supply safety devices for use by persons while involved in carrying out the practice;
(b)details of the devices to be supplied;
(c)details of how, and when, the devices are to be used;
(d)details of the intervals at which the devices are to be checked for wear and tear, and correct operation;
(e)details of the persons who will be engaged to check the devices, described by reference to the abilities of the persons to perform the task.
(2)In this section—
safety device means a device that, when used by a person while involved in carrying out a radiation practice, reduces the exposure of the person to radiation attributable to the carrying out of the practice, but does not include personal protective equipment.

22Supply of personal protective equipment—Act, s 28(6)

For the Act, section 28(6), the following are radiation safety and protection measures for the carrying out of a radiation practice—
(a)a requirement that the possession licensee in possession of the source, under the licence, for the practice supply personal protective equipment for wearing by—
(i)persons while involved in carrying out the practice; or
(ii)anyone exposed to radiation in the carrying out of the practice;
(b)details of the type of equipment to be supplied to the persons, described by reference to the nature of their involvement in the carrying out of the practice;
(c)details of how, and when, the equipment is to be worn by the persons;
(d)details of the intervals at which the equipment is to be checked for wear and tear, and correct operation;
(e)details of the persons who will be engaged to check the equipment, described by reference to the abilities of the persons to perform the task;
(f)details of the persons who will be required to wear the equipment.

23Record in a register—Act, s 28(6)

For the Act, section 28(6), a radiation safety and protection measure for the carrying out of a radiation practice is a requirement that the use licensee allowed to use the source, under the licence, for the practice record in a register, supplied and under the control of the possession licensee who possesses the source, the following—
(a)the names of persons who use the source to carry out the practice;
(b)if the source is an unsealed radioactive substance—details of any disposal of radioactive material that happens in the carrying out of the practice;
(c)details of—
(i)any quality control procedures undertaken for—
(A)the source; and
(B)if the source is a sealed radioactive substance incorporated in a sealed source apparatus—the apparatus; and
(C)if the practice involves the production of images—any ancillary imaging equipment used in connection with the use of the source to carry out the practice; and
(ii)the outcomes of the procedures.

24Supply of personal monitoring devices—Act, s 28(6)

(1)This section applies if, under a radiation safety and protection plan for a radiation practice, a personal monitoring device is required to be supplied to a person.

Note—

The Act, section 28(3) states the circumstances in which a radiation safety and protection plan for a radiation practice must provide for the supply of a personal monitoring device to a person.
(2)For the Act, section 28(6), the following are radiation safety and protection measures for the carrying out of the practice—
(a)details of the persons who are required to wear the device, described by reference to the nature of their involvement in the carrying out of the practice;
(b)details of how, when and where the device is to be worn;
(c)details of where the device is to be stored when not being worn;
(d)details of the intervals at which the device is to be assessed;
(e)details of the persons who are to perform the assessment, described by reference to the abilities of the persons to perform the task.

Division 2 Radiation safety and protection measures for certain radiation practices

25Radiation practices involving the use of ionising radiation sources—Act, s 28(6)

(1)This section applies if a radiation practice involves the use of an ionising radiation source.
(2)For the Act, section 28(6), the following are radiation safety and protection measures for the carrying out of the practice—
(a)a requirement that the possession licensee in possession of the source, under the licence, for the practice supply personal alarm dosemeters for use by persons while involved in carrying out the practice;
(b)details of the persons who are required to use the dosemeters, described by reference to the nature of their involvement in the carrying out of the practice;
(c)details of how, and when, the dosemeters are to be used by the persons;
(d)details of the dosemeters, having the sensitivity, accuracy, range and energy response appropriate to the source, that will be used;
(e)details of the intervals, of not more than 1 year, at which the dosemeters are to be checked for sensitivity, accuracy, range and energy response;
(f)if a personal alarm dosemeter is repaired or suspected to have been damaged—a requirement that the dosemeter not be used unless it is first checked for sensitivity, accuracy, range and energy response;
(g)details of the persons who will be engaged to check the sensitivity, accuracy, range and energy response of the dosemeters, described by reference to the abilities of the persons to perform the task.
(3)In this section—
personal alarm dosemeter means a device that produces a visual or audible signal when—
(a)a radiation dose received by the device is more than a certain dose level; or
(b)a radiation dose received by the device in a particular period is more than a certain dose level.

26Radiation practices involving the use or storage of unsealed radioactive substances—Act, s 28(6)

(1)This section applies to a radiation practice involving the use or storage of unsealed radioactive substances at premises.
(2)For the Act, section 28(6), the following are radiation safety and protection measures for the carrying out of the practice—
(a)details stating how the premises, and persons or things at the premises, are to be monitored to detect or minimise contamination of the premises, persons or things;
(b)details about how, and the period for which, contaminated cleanable things at the premises are to be stored at the premises before removal from the premises for cleaning;
(c)details about how waste radioactive material, produced in carrying out the practice, is to be dealt with before its disposal;
(d)details about how the amount of waste radioactive material produced in carrying out the practice is to be minimised.
(3)For subsection (2)(a), the measures must include details of the monitoring equipment, having the sensitivity, accuracy, range and energy response appropriate to the contamination to be monitored, that will be used.
(4)For subsection (2)(c), the measures must include the following—
(a)the method to be used to minimise the activity of the radionuclide in, and volume of, the material;
(b)if the material is to be stored—how the material is to be sorted for storage, having regard to—
(i)its half-life, volume, and physical and chemical properties; and
(ii)the concentration of the radionuclide in the material.
(5)In this section—
cleanable thing, at premises, means a thing that, to be cleaned, needs to be removed from the premises.
contamination, of a person, premises or thing, means the lodgement, attachment or incorporation of radioactive material on, to or in the person, premises or thing.

27Certain radiation practices involving the use of ionising radiation sources—Act, s 28(6)

(1)This section applies to a radiation practice involving the use of an ionising radiation source to carry out a radiation practice, other than—
(a)the use of an ionising radiation apparatus for—
(i)a diagnostic procedure involving the irradiation of a person; or
(ii)chemical analysis; or
(b)the use of a sealed source apparatus for chemical analysis; or
(c)the use of a cabinet radiation apparatus or enclosed radiation apparatus for its intended use.
(2)For the Act, section 28(6), the following are radiation safety and protection measures for the carrying out of the practice—
(a)a requirement that the possession licensee in possession of the source, under the licence, for the practice supply radiation monitoring equipment for use by persons while involved in carrying out the practice;
(b)details of how the equipment is to be used;
(c)details of the equipment, having the sensitivity, accuracy, range and energy response appropriate to the radiation source, that will be used;
(d)details of how the licensee will ensure the sensitivity, accuracy, range and energy response of the equipment to be used are maintained;
(e)details of the intervals, of not more than 1 year, at which the equipment is to be checked for sensitivity, accuracy, range and energy response;
(f)if the equipment is repaired or suspected to have been damaged—a requirement that the equipment must not be used unless it is first checked for sensitivity, accuracy, range and energy response;
(g)details of the persons who will be engaged to check the sensitivity, accuracy, range and energy response of the equipment, described by reference to the abilities of the persons to perform the task.
(3)In this section—
radiation monitoring equipment means equipment that measures the amount of radiation emitted from radioactive substances or ionising radiation apparatus in a particular period.

28[Repealed]

s 28 exp 30 December 2014 (see s 94A)

29Radiation practices involving the carrying out of a diagnostic, therapeutic or cosmetic procedure involving the irradiation of a person—Act, s 28(6)

(1)This section applies to a radiation practice involving the use of a radiation source to carry out a diagnostic, therapeutic or cosmetic procedure involving the irradiation of a person (the treated person).
(2)For the Act, section 28(6), the following are radiation safety and protection measures for the carrying out of the practice—
(a)a requirement that the possession licensee in possession of the source, under the licence, for the practice supply personal protective equipment for wearing by the treated person while undergoing the procedure;
(b)a requirement that the use licensee who, under the licence, uses the source to carry out the procedure ensures that the treated person wears the equipment while undergoing the procedure;
(c)details of the equipment to be supplied;
(d)a requirement that the use licensee record in a register, supplied and under the control of the possession licensee, the following details about each exposure of the treated person to radiation while undergoing the procedure—
(i)the date of use of the source to carry out the procedure;
(ii)details of the procedure;
(iii)if, as part of the procedure, the treated person was injected with a radioactive substance or a radioactive substance was administered to or implanted in the person—details of the substance;
(e)if the carrying out of the procedure results in the production of radiographs or nuclear medicine images—
(i)a requirement that the images produced be permanently marked with relevant information; and
(ii)details of the way in which the marking is to be made.
(3)In this section—
permanently marked, for an image, means the image is marked in a way that leaves a permanent record on the image.
relevant information, for a nuclear medicine image, means the following information—
(a)the name, or identifying mark, of the use licensee;
(b)the name, or identifying mark, of the possession licensee;
(c)the address, or identifying mark, of the premises at which the image was produced;
(d)the name, gender and date of birth of the treated person;
(e)the date the image was produced;
(f)details of the radiopharmaceuticals administered to, or injected into, the treated person for the production of the image;
(g)enough information to enable the correct interpretation of the image.
relevant information, for a radiograph with a surface area of 45cm2 or more, means the following information—
(a)the name, or identifying mark, of the use licensee;
(b)the name, or identifying mark, of the possession licensee;
(c)the address, or identifying mark, of the premises at which the radiograph was produced;
(d)the name, gender and date of birth of the treated person;
(e)the date the radiograph was produced;
(f)enough information to enable the correct interpretation of the radiograph.
relevant information, for a radiograph with a surface area of less than 45cm2, means a marking that identifies, or helps in the identification of, the treated person.

30Radiation practices involving the carrying out of a diagnostic or therapeutic procedure involving the irradiation of a person—Act, s 28(6)

(1)This section applies to a radiation practice involving the use of a radioactive substance to carry out a diagnostic or therapeutic procedure involving the irradiation of a person.
(2)For the Act, section 28(6), a radiation safety and protection measure for the carrying out of the practice is a measure that provides guidance about the duration of the procedure.

31Radiation practices resulting in the production of the radionuclide radon-222—Act, s 28(6)

(1)This section applies to a radiation practice that results in the production of the radionuclide radon-222.
(2)For the Act, section 28(6), a radiation safety and protection measure for the carrying out of the practice is a requirement that the premises in which the practice is carried out are ventilated in a way that prevents the concentration of the radionuclide being more than 200Bq per cubic metre.

Division 3 Other particulars to be stated in radiation safety and protection plans

32Radiation safety officers—Act, s 28(2)(g)

(1)This section applies if a possession licensee, under the licence, possesses a radiation source for a radiation practice.
(2)For the Act, section 28(2)(g), the radiation safety and protection plan for the practice must state the maximum intervals at which a radiation safety officer appointed by the licensee for the practice is to monitor or assess the source, or premises at which the practice is being carried out, to identify whether the relevant radiation safety standard for the source or premises is being complied with.

33[Repealed]

s 33 exp 30 December 2014 (see s 94A)

Part 6 Security requirements for a security enhanced source

Division 1 Threat levels

34Meaning of threat level

(1)A threat level is an indicator of the likelihood and consequences of a person acquiring a security enhanced source for a malicious purpose.
(2)For this part, the threat level at a particular time is the threat level decided by the National Threat Assessment Centre and communicated to the commissioner of police.

Note—

The threat level is ordinarily described as any of the following—
extreme
high
medium
low
very low
negligible.
(3)In this section—
National Threat Assessment Centre means the entity of that name administered within the Australian Security Intelligence Organisation.

Division 2 Security measures for a security enhanced source

35Matters to be included in a security plan—Act, s 34A

The matters stated in this division are the security measures and particulars that must be stated in a security plan.

36Storage and use of a security enhanced source

The security plan must include details for the secure storage and use of a security enhanced source, including—
(a)the location of the security enhanced source in the building or facility where it is—
(i)stored; or
(ii)used in the carrying out of a radiation practice; and
(b)a plan of the building or facility in which the security enhanced source is—
(i)stored; or
(ii)used in the carrying out of a radiation practice; and
(c)the administrative security actions proposed to be taken for each threat level to protect the area in which the source is located.

37Control of access to, or use of, a security enhanced source

The security plan must include a statement providing details of how access to, or use of, a security enhanced source is to be controlled for each threat level, including—
(a)the supervision requirements for persons who may be allowed access to a security enhanced source; and
(b)the type of check each person will be required to undertake to gain access to the source; and
(c)the physical barriers to deter and delay unauthorised access to the source.

Examples of physical barriers—

tamper-proof locks, bolts, armoured cupboards

38Security equipment

The security plan must include a statement providing details of security equipment used for each threat level to protect a security enhanced source, including—
(a)each type of security equipment to be installed including details of—
(i)how and when the equipment is to be used; and
(ii)the intervals at which the equipment is to be checked for wear and tear and correct operation; and
(iii)the outcome of an equipment check; and
(iv)the person who will be required to check the equipment, described by reference to the abilities of the person to perform the task; and
(b)procedures to be followed before, during and after a technical service of the security equipment.

39Security persons and surveillance

The security plan must include a statement providing details of security persons and surveillance used for each threat level to guard a security enhanced source, including—
(a)the duties and responsibilities allocated to persons in charge of security; and
(b)how surveillance of a security enhanced source will be conducted.

40Security-related information and other records

(1)The security plan must include a statement providing details for each threat level of how the possession licensee proposes to record and maintain—
(a)inventories and documents related to the management of security enhanced sources; and
(b)details about ensuring the security of security-related information, including—
(i)who is responsible for the information; and
(ii)what information must be kept secure; and
(iii)where the information is kept; and
(iv)who is allowed access to the information; and
(v)how the information is kept secure.
(2)In this section—
security-related information means information about the measures, systems, infrastructure and other things used for each threat level to secure a security enhanced source.

Example of security-related information—

information related to a specific security system, pin codes, passwords or where keys are stored

41Security response arrangements

The security plan must include a statement providing details of—
(a)the contingency and security response arrangements including the process for notification of a security breach; and
(b)the actions to be taken in the event of a change in the threat level.

Division 3 Transport security measures for a security enhanced source

42Matters to be included in a transport security plan—Act, s 34H

The matters stated in this division are the transport security measures and particulars that must be stated in a transport security plan.

43Purpose and risk identification

The transport security plan must include a statement providing details of—
(a)the purpose or reason for which the source is being transported; and
(b)the administrative security actions proposed to be taken for each threat level to address security risks identified.

44Transportation methods and procedures

The transport security plan must include a statement providing details for each threat level of—
(a)the vehicle in which the source will be transported and the arrangements for securing the transport during the journey or while stopped en route; and
(b)the arrangements for notifying, as considered appropriate, a local police service or the regulatory authority of each jurisdiction in which the source will be transported; and
(c)the name, business address and after-hours contact details for the consignor, consignee, carrier and, where used, guard or police service; and
(d)the means of communicating between the parties involved in the transport of the source; and
(e)the contingency or emergency procedures for vehicle accidents or breakdown; and
(f)the planned principal route and an alternative route.

45Transport security equipment

The transport security plan must include a statement providing details of the type of security-related equipment to be used for each threat level, including—
(a)how and when the equipment is to be used; and
(b)the intervals at which the equipment is to be checked for wear and tear and correct operation; and
(c)the outcomes of the checking procedures; and
(d)the person who will be required to check the equipment, described by reference to the abilities of the person to perform the task.

46Transport security persons

The transport security plan must include a statement providing details of the security persons used for each threat level to guard a security enhanced source during transport, including—
(a)allocated duties and responsibilities for persons in relation to the security measures and particulars; and
(b)the type of security check each person will be required to undergo in order to undertake their transport-related activities with the source; and
(c)the security briefing for persons involved in the transport of the source including the nature of the threat, the threat level, contingency procedures and security response arrangements.

47Control of access to a security enhanced source during transport

The transport security plan must include a statement providing details for each threat level of—
(a)how access to the source will be controlled; and
(b)the supervision requirements of persons who may be allowed access to a security enhanced source.

48Security-related information about transport

(1)The transport security plan must include a statement providing details for each threat level of how security-related information will be secured, including—
(a)who is responsible for the information; and
(b)what information must be kept secure; and
(c)where the information is kept; and
(d)who is allowed access to the information; and
(e)how the information is kept secure.
(2)In this section—
security-related information means information about the measures, systems, infrastructure and other things used for each threat level to secure a security enhanced source during transport.

Example of security-related information—

information related to travel routes, pin codes, passwords or where keys are stored

s 48 amd 2012 SL No. 246 s 5

49Transport security response arrangements

The transport security plan must include a statement providing details of—
(a)the contingency and transport security response arrangements including the process for notification of a security breach; and
(b)the actions to be taken in the event of a change in the threat level.

Part 7 Radiation safety officers

50Qualifications—Act, s 36(3)

For the Act, section 36(3), for each radiation practice stated in schedule 5, column 1, the qualification stated opposite the radiation practice in schedule 5, column 2 is prescribed.

51Functions—Act, s 37(2)(b)(iii)

For the Act, section 37(2)(b)(iii), the other persons are—
(a)persons who observe the carrying out of the radiation practice, other than persons stated in the Act, section 37(2)(b)(i) and (ii); and
(b)if the radiation practice is a diagnostic or therapeutic procedure involving the irradiation of a person (the treated person)—persons involved in carrying out the procedure, other than the treated person and persons stated in the Act, section 37(2)(b)(i) and (ii).

Part 8 Radiation monitoring

52Information in personal monitoring records—Act, s 38(4)(b)

For the Act, section 38(4)(b), the other information is the following—
(a)the name, gender and date of birth of the monitored person;
(b)the name and postal address of the licensee;
(c)the date the monitored person started to be monitored for any radiation doses received in relation to the carrying out of the practice;
(d)the date the monitored person stopped being monitored for any radiation doses received in relation to the carrying out of the practice;
(e)details of the basis for the monitored person being required to be provided, or wear, a personal monitoring device;
(f)the type of radiation to which the monitored person has been exposed in relation to the carrying out of the practice;
(g)the period the assessment of a personal monitoring device worn by the monitored person, in relation to the carrying out of the practice, relates to;
(h)the estimated total effective dose, determined as a result of the assessment, for the monitored person for the period;
(i)details of the methodology used in the assessment.

Part 9 Radiation dose limits

Division 1 Ionising radiation

53Radiation dose limits applying for occupational exposure of persons—Act, ss 37(2)(c)(i), 41(5), 42(2), 127(1)(b), 132(4)(b) and 133(2)(c)

(1)This section applies if a possession licensee, under the licence, possesses an ionising radiation source for a radiation practice.
(2)For the Act, sections 37(2)(c)(i), 41(5), 42(2), 127(1)(b), 132(4)(b) and 133(2)(c), the radiation dose limits applying to the occupational exposure of a person to ionising radiation while involved in carrying out the practice are as follows—
(a)the average of the annual total effective doses for the person, over a 5-year period, must not be more than 20mSv per year;
(b)the total effective dose for the person must not be more than 50mSv per year;
(c)the equivalent dose for each lens of the person’s eyes must not be more than 150mSv per year;
(d)the equivalent dose for each of the person’s hands and feet must not be more than 500mSv per year;
(e)the equivalent dose for a square centimetre of the person’s skin must not be more than 500mSv per year.
(3)For the Act, sections 37(2)(c)(i), 41(5), 42(2), 127(1)(b), 132(4)(b) and 133(2)(c), the radiation dose limits applying to the occupational exposure of a person to ionising radiation emitted from the source, other than while involved in carrying out the practice, are as follows—
(a)the total effective dose for the person must not be more than 1mSv per year;
(b)the equivalent dose for each lens of the person’s eyes must not be more than 15mSv per year;
(c)the equivalent dose for a square centimetre of the person’s skin must not be more than 50mSv per year.

54Radiation dose limits applying for public exposure of persons—Act, ss 37(2)(c)(i), 42(2), 127(1)(b), 132(4)(b) and 133(2)(c)

(1)This section applies if a possession licensee, under the licence, possesses an ionising radiation source for a radiation practice.
(2)For the Act, sections 37(2)(c)(i), 42(2), 127(1)(b), 132(4)(b) and 133(2)(c), the radiation dose limits applying to the public exposure of a person to ionising radiation while the practice is carried out are as follows—
(a)the total effective dose for the person must not be more than 1mSv per year;
(b)the equivalent dose for each lens of the person’s eyes must not be more than 15mSv per year;
(c)the equivalent dose for a square centimetre of the person’s skin must not be more than 50mSv per year.
(3)Subsection (2) does not apply if the person is exposed—
(a)if the practice is a diagnostic or therapeutic procedure involving the irradiation of another person—while involved in carrying out the procedure; or
(b)while involved in carrying out the practice, as a voluntary participant in health-related research.

55Radiation dose limits applying for the carrying out of a diagnostic or therapeutic procedure involving the irradiation of a person—Act, ss 37(2)(c)(i), 41(5), 127(1)(b), 132(4)(b) and 133(2)(c)

(1)This section applies if—
(a)a use licensee, under the licence, uses an ionising radiation source to carry out a diagnostic or therapeutic procedure involving the irradiation of a person (the treated person); and
(b)a person, other than the treated person, involved in carrying out the procedure is exposed to ionising radiation.
(2)For the Act, sections 37(2)(c)(i), 41(5), 127(1)(b), 132(4)(b) and 133(2)(c), the radiation dose limit applying to the exposure is a total effective dose of 5mSv per year.
(3)Subsection (2) does not apply if the exposure is an occupational exposure to the radiation.

56Supply of personal monitoring devices—Act, s 28(3)

For the Act, section 28(3), the radiation dose limit for ionising radiation is a total effective dose of 1mSv per year.

57Pregnant women—Act, ss 37(2)(c)(i), 41(5), 42(2), 127(1)(b), 132(4)(b) and 133(2)(c)

(1)This section applies if a possession licensee, under the licence, possesses an ionising radiation source for a radiation practice.
(2)For the Act, sections 37(2)(c)(i), 41(5), 42(2), 127(1)(b), 132(4)(b) and 133(2)(c), the radiation dose limit applying to the occupational exposure of a pregnant woman to ionising radiation while involved in carrying out the practice is a total effective dose of 1mSv per year.
(3)However, for the Act, section 127(1)(b), subsection (2) only applies if the inspector is aware, or ought reasonably be aware, the woman is pregnant.
(4)Also, subsection (2) does not apply if—
(a)for the Act, section 41(5)—the use licensee who, under the licence, uses the source to carry out the practice is not aware, or could not reasonably be aware, the woman is pregnant; or
(b)for the Act, section 42(2)—the person carrying out the practice is not aware, or could not reasonably be aware, the woman is pregnant.

58Mineral substances that are not radioactive substances

(1)This section applies to a person who possesses a mineral substance that is a radioactive material that is not a radioactive substance.
(2)The person must ensure that another person does not receive a total effective dose from ionising radiation emitted from the substance that is—
(a)for public exposure of the other person—more than 1mSv per year; or
(b)for occupational exposure of the other person—more than 20mSv per year.

Maximum penalty—20 penalty units.

Division 2 Non-ionising radiation

59Functions of radiation safety officers—Act, ss 37(2)(c)(ii)

For the Act, section 37(2)(c)(ii), the radiation dose limits for non-ionising radiation emitted by a laser apparatus used to carry out a diagnostic, therapeutic or cosmetic procedure involving the irradiation of a person are stated in tables 6 and 8 of the laser standard.

60Carrying out diagnostic or therapeutic procedures involving the irradiation of a person—Act, s 41(5)

For the Act, section 41(5), the radiation dose limits for non-ionising radiation emitted by a laser apparatus used to carry out a diagnostic or therapeutic procedure involving the irradiation of a person are stated in tables 6 and 8 of the laser standard.

61Carrying out cosmetic procedures involving the irradiation of a person—Act, s 42(2)

For the Act, section 42(2), the radiation dose limits for non-ionising radiation emitted by a laser apparatus used to carry out a cosmetic procedure involving the irradiation of a person are stated in tables 6 and 8 of the laser standard.

62Seizing dangerous things—Act, ss 127(1)(b), 132(4)(b) and 133(2)(c)

For the Act, sections 127(1)(b), 132(4)(b) and 133(2)(c), the radiation dose limits for non-ionising radiation emitted by a laser apparatus used to carry out a diagnostic, therapeutic or cosmetic procedure involving the irradiation of a person are stated in tables 6 and 8 of the laser standard.

Part 10 Authorised persons

63Authorised persons for diagnostic or therapeutic procedures—Act, s 41

For the Act, section 41(1)—
(a)for a diagnostic procedure stated in schedule 6, part 1, column 1, a person stated in schedule 6, part 1, column 2 opposite the procedure is an authorised person; and
(b)for a therapeutic procedure stated in schedule 6, part 2, column 1, a person stated in schedule 6, part 2, column 2 opposite the procedure is an authorised person.

64Physician’s assistants authorised under practice plans—Act, s 41

A physician’s assistant is authorised to request a diagnostic procedure stated in schedule 6, part 1, column 1 if—
(a)the practice plan developed for the physician states that the physician’s assistant may request the diagnostic procedure; and
(b)the physician’s assistant requests the diagnostic procedure under the supervision of his or her supervising medical officer; and
(c)the supervising medical officer is authorised under section 63 to request the diagnostic procedure stated in schedule 6, part 1, column 1.

Part 11 Banned radiation sources and radiation practices

pt 11 hdg amd 2012 SL No. 246 s 6

64ABanned radiation sources for possession—Act, s 47

For the Act, section 47—
(a)a relevant solarium is prescribed as a banned radiation source in relation to the possession of the relevant solarium; and
(b)a person must not apply for a possession licence for a relevant solarium; and
(c)the chief executive must not grant a possession licence for a relevant solarium.

s 64A ins 2012 SL No. 246 s 7

65[Repealed]

s 65 amd 2013 SL No. 288 s 3

exp 30 December 2014 (see s 94A)

Part 12 Exemptions

Division 1 Requirement for use licence

66Prescribed radiation practices—Act, s 13(3), definition prescribed radiation practice

(1)For the Act, section 13(3), definition prescribed radiation practice, the following are prescribed radiation practices—
(a)industrial radiography involving the use of an ionising radiation source;
(b)borehole logging involving the use of a sealed source apparatus;
(c)density-gauging, or moisture-gauging, for geo-technical purposes, involving the use of a sealed source apparatus;
(d)the preparation of a radioactive substance or radiation apparatus, or assembly of a sealed source apparatus, for use in carrying out a diagnostic or therapeutic procedure involving the irradiation of a person;
(e)the commissioning, maintenance or repair of radiation sources or sealed source apparatus;
(f)the compliance testing of a radiation source by a qualified accredited person for a radiation source of that type, involving the use of the source or another radiation source;
(g)the compliance testing of premises by a qualified accredited person for premises of that type, involving the use of a radiation source;
(h)the undertaking of quality control procedures, in relation to—
(i)a radiation source, involving the use of another radiation source; or
(ii)a sealed source apparatus, involving the use of a radiation source.
(2)In this section—
compliance testing, of a radiation source or premises, means assessing whether the source or premises complies with the relevant radiation safety standard.
qualified accredited person, for a type of radiation source or premises, means an accredited person who, under the person’s accreditation certificate, is allowed to issue a certificate of compliance for the type of radiation source or premises.

67Training—Act, s 13(2)(b)(ii)

For the Act, section 13(2)(b)(ii), the following is training—
(a)training at an educational institution, other than training involving the actual irradiation by the trainee of a person as part of a diagnostic or therapeutic procedure;
(b)undertaking a course or subject stated in schedule 7.

Division 2 Radiation sources

68Exemption from requirement for possession licence—Act, s 210

For the Act, section 210, a radioactive substance containing the radionuclide nickel-63 or hydrogen-3 is exempt from the Act, section 12 if—
(a)it is incorporated in a sealed source apparatus; and
(b)the apparatus is used for gas chromatography.

69Exemption from requirement for use licence—Act, s 210

(1)For the Act, section 210, the following radiation sources are exempt from the Act, section 13—
(a)if a sealed source apparatus, incorporating a sealed radioactive substance, is used for chemical analysis or industrial gauging—the substance;
(b)a radiation apparatus used for industrial gauging;
(c)a cabinet radiation apparatus used for its intended use;
(d)an enclosed radiation apparatus used for its intended use;
(e)an ionising radiation source designed only for irradiating things, but not including use of the source by a person who is carrying out commissioning, maintenance or repair of the source;
(f)a sealed radioactive substance, having an activity of not more than 370MBq, used for—
(i)calibration checks of measuring instruments; or
(ii)quality control procedures undertaken for—
(A)another radiation source or a sealed source apparatus; or
(B)if another radiation source is used to carry out a radiation practice involving the production of images—any ancillary imaging equipment used in connection with the use of the other source to carry out the practice;
(g)a sealed radioactive substance, having an activity of not more than 4MBq, used for transferring anatomical landmarks to images produced using a gamma camera;
(h)a radioactive substance, having an activity of not more than 500kBq, used for an in vitro test;
(i)a sealed radioactive substance used for static elimination;
(j)a fully enclosed analytical radiation apparatus used for its intended use;
(k)a laser apparatus designed only for puncturing a person’s skin to obtain capillary blood samples but not including use of the apparatus by a person who is carrying out maintenance or repair of the apparatus.
(2)To remove any doubt, it is declared that subsection (1)(e) does not apply to an ionising radiation source designed for irradiating individuals.
(3)In this section—
fully enclosed analytical radiation apparatus means an ionising radiation apparatus, used for physical or chemical analysis, in which—
(a)the radiation source, the sample for analysis and equipment irradiated in the analytical process are enclosed in a chamber, or coupled chambers, designed to prevent any person being exposed to the primary x-ray beam of the source during normal operation of the apparatus; and
(b)the sample for analysis is transferred from a sample port to the chamber in which it is irradiated by a mechanism that prevents any person gaining access to the chamber during normal operation of the apparatus.

70Exemption from requirement for transport licence—Act, s 210

(1)For the Act, section 210, a radioactive substance enclosed in an excepted package is exempt from the Act, sections 14 and 15 if the package is transported in accordance with the transport code of practice.
(2)Subsection (3) applies to a sealed radioactive substance incorporated in a sealed source apparatus, if the apparatus is used by a use licensee under a use licence to carry out 1 of the following radiation practices—
(a)borehole logging;
(b)density-gauging, or moisture-gauging, for geo-technical purposes;
(c)industrial radiography.
(3)For the Act, section 210, the substance is exempt from the Act, sections 14 and 15 if the apparatus is transported by the licensee in accordance with the transport code of practice.
(4)In this section—
excepted package has the meaning given in the transport code of practice.

71Smoke detectors—Act, s 210

(1)For the Act, section 210—
(a)a radioactive substance incorporated in a domestic smoke detector is exempt from the Act, sections 12, 13 and 26; and
(b)a radioactive substance incorporated in an ionisation chamber smoke detector that is not a domestic smoke detector is exempt from the Act, sections 12 and 13 if the detector was—
(i)acquired before 1 January 2000; or
(ii)manufactured in accordance with AS 1603.2-1997 (Automatic fire detection and alarm systems, Part 2: Point type smoke detectors).
(2)To remove any doubt, it is declared that subsection (1) does not apply while the detector is being manufactured or repaired.
(3)In this section—
domestic smoke detector means an ionisation chamber smoke detector containing the radionuclide americium-241 having an activity of not more than 37kBq and manufactured in accordance with AS 3786-1993 (Smoke alarms), second edition.

72Certain radioactive substances, incorporated in items to produce light—Act, s 210

(1)For the Act, section 210—
(a)a radioactive substance containing the radionuclide promethium-147 or hydrogen-3, incorporated in an item to produce light is exempt from the Act, sections 12, 13 and 26; and
(b)a radioactive substance containing the radionuclide radium-226, incorporated in an item to produce light is exempt from the Act, sections 12 and 13.
(2)Subsection (1) does not apply if the item is a gaseous tritium light device.
(3)Also, to remove doubt, it is declared that subsection (1) does not apply while the item is being manufactured or repaired.

73Gaseous tritium light devices—Act, s 210

For the Act, section 210, a radioactive substance containing the radionuclide hydrogen-3 with an activity of less than 74GBq, incorporated in a gaseous tritium light device, is exempt from the Act, sections 12 and 13 if the device—
(a)is being used as a safety, or warning, sign; and
(b)complies with sections 2, 4 and 5 of the document called ‘Appendix XXXIX—Recommendations for exemptions from licensing of gaseous tritium light devices’ published by NHMRC.

74Depleted uranium—Act, s 210

(1)For the Act, section 210, depleted uranium is exempt from the Act, sections 12, 14 and 15 if it is—
(a)being used as ballast in an aircraft or ship; and
(b)totally encased in a metallic sheath; and
(c)in solid massive form.
(2)In this section—
depleted uranium means uranium containing less than 0.72% of the radionuclide uranium-235.

75Sealed radioactive substances used in teaching—Act, s 210

(1)This section applies to a sealed radioactive substance containing a radionuclide mentioned in column 1 of the following table if the activity of the radionuclide is not more than the activity mentioned in column 2 of the table shown opposite the radionuclide—

Table

Column 1

Column 2

Radionuclide

Activity (kBq)

cobalt-60

200

strontium-90

80

caesium-137

200

radium-226

20

americium-241

20

(2)For the Act, section 210, the substance is exempt from the Act, section 13 if it is being used for teaching the characteristics and properties of radiation or radiation sources.

76Minerals—Act, s 210

(1)This section applies to a mineral that is a radioactive substance.
(2)For the Act, section 210, the mineral is exempt from the Act, section 12 if—
(a)it emits radiation at a level not more than 5 micrograys per hour, measured at a distance of 10cm from its surface; and
(b)it is being used—
(i)as a sample in teaching; or
(ii)for display as a geological specimen.

77Abrasive blasting material containing radionuclides—Act, s 210

(1)This section applies to abrasive blasting material, containing radionuclides, if it is being used in abrasive blasting.
(2)Subsection (3) applies if—
(a)the material is a radioactive substance; and
(b)the material contains thorium or uranium radionuclides.
(3)For the Act, section 210, the material is exempt from the Act, section 12 if the amount worked out, using the formula, in relation to the material is not more than 1—

Formula

where—

Th means the total concentration, stated in Bq per gram, of any thorium radionuclides and their progeny contained in the material.
U means the total concentration, stated in Bq per gram, of any uranium radionuclides and their progeny contained in the material.

(4)Further, material that is, under subsection (3), exempt from the Act, section 12 is also exempt from the Act, section 26 if the gross alpha and gross beta concentrations in the leachate, determined as a result of carrying out the TCLP in relation to the material, are not each more than the amount worked out by multiplying the relevant concentration stated in the ‘Australian Drinking Water Guidelines’, jointly prepared by NHMRC and NRMMC, by 10.
(5)In this section—
abrasive blasting material means material that could reasonably be used for abrasive blasting.

78Mineral substances—Act, s 210

(1)Subsection (2) applies to a mineral substance being disposed of, other than into the air, water or sewerage system.
(2)The substance is exempt from the Act, section 26 if—
(a)the gross alpha and gross beta concentrations in the leachate, determined as a result of carrying out the TCLP in relation to the substance, are not each more than the amount worked out by multiplying the relevant concentration stated in the ‘Australian Drinking Water Guidelines’, jointly prepared by NHMRC and NRMMC, by 10; and
(b)for a substance that contains—
(i)only 1 of the radionuclides stated in schedule 1, column 1—the concentration of the radionuclide is less than the amount worked out by multiplying the concentration stated in schedule 1, column 2 shown opposite the radionuclide by 10; or
(ii)more than 1 of the radionuclides stated in schedule 1, column 1—the substance’s disposal factor is not more than 1.
(3)In this section—
disposal factor, for a mineral substance containing more than 1 of the radionuclides stated in schedule 1, column 1, means the total of the amounts worked out by applying the formula to each of the radionuclides—

equation

where—
C, for a radionuclide, means the radionuclide’s concentration, measured in Bq per gram.
MC, for a radionuclide, means the amount worked out by multiplying the concentration stated in schedule 1, column 2 shown opposite the radionuclide by 10.

79Persons who have been injected with a radioactive substance etc. as part of a diagnostic or therapeutic procedure—Act, s 210

(1)This section applies if—
(a)a person has been injected with a radioactive substance, or a radioactive substance has been administered to or implanted in a person, as part of a diagnostic or therapeutic procedure; and
(b)the person disposes of the substance’s radionuclide as part of his or her bodily waste.
(2)For the Act, section 210, the bodily waste is exempt from the Act, section 26 only to the extent that it is disposed of by the person.

Note—

This section does not exempt another person from the requirements of the Act, section 26 for the disposal of the bodily waste.

80Radionuclide krypton-85, incorporated in a cold cathode gas discharge tube—Act, s 210

(1)For the Act, section 210, a radioactive substance containing the radionuclide krypton-85, incorporated in a cold cathode gas discharge tube, is exempt from the Act, sections 12, 13 and 26.
(2)To remove any doubt, it is declared that subsection (1) does not apply while the tube is being manufactured or repaired.

80A[Repealed]

s 80A ins 2013 SL No. 288 s 4

exp 30 June 2015 (see s 80A(2))

Part 13 Registers

81Register of licensees—Act, s 207

(1)For the Act, section 207(2), the register the chief executive must keep about licensees, other than prescribed licensees, must contain the following information about a licensee—
(a)the licensee’s name;
(b)the licence number;
(c)the licence type;
(d)the expiry date of the licence;
(e)any conditions on the licence;
(f)if the licensee is a possession licensee—
(i)particulars of the radiation source the licensee is allowed to possess; and
(ii)the radiation practice for which the licensee is allowed to possess the source;
(g)if the licensee is a use licensee—
(i)particulars of the radiation source the licensee is allowed to use; and
(ii)the radiation practice the licensee is allowed to carry out using the source;
(h)if the licensee is a transport licensee—
(i)particulars of the radioactive substance the licensee is allowed to transport; and
(ii)how the substance is to be transported; and
(iii)the amount of the substance the licensee is allowed to transport at a time.
(2)Also, for section 207(1)(f) of the Act, the register must contain the following information about a prescribed licensee whose licence has been suspended or cancelled—
(a)if the licensee’s licence has been cancelled—
(i)the licensee’s name; and
(ii)the day the decision to cancel the licence takes effect;
(b)if the licensee’s licence has been suspended and the period of suspension has not ended—
(i)the licensee’s name; and
(ii)the day the decision to suspend the licence takes effect; and
(iii)the period of the suspension.

s 81 amd 2019 SL No. 117 s 20

82Register of accredited persons—Act, s 207

For the Act, section 207(2), the register the chief executive must keep about accredited persons must contain the following information about an accredited person—
(a)the accredited person’s name;
(b)the accreditation certificate number;
(c)the expiry date of the accreditation certificate;
(d)any conditions on the accreditation certificate;
(e)the type of radiation source or premises for which the accredited person may issue a certificate;
(f)the accredited person’s contact details.

Examples of contact details—

address, telephone number, facsimile number, email address

83Register of qualified persons—Act, s 207

For the Act, section 207(2), the register the chief executive must keep about qualified persons must contain the following information about a qualified person—
(a)the qualified person’s name;
(b)the radiation safety officer certificate number;
(c)the expiry date of the radiation safety officer certificate;
(d)any conditions on the radiation safety officer certificate;
(e)the radiation practice for which the qualified person may perform the functions of a radiation safety officer.

84Register of inspectors—Act, s 207

For the Act, section 207(2), the register the chief executive must keep about inspectors must contain the following information about an inspector—
(a)the inspector’s name;
(b)if the inspector is appointed for a term—the term of the appointment;
(c)any conditions of the inspector’s appointment.

85Register of State radiation analysts—Act, s 207

For the Act, section 207(2), the register the chief executive must keep about State radiation analysts must contain the following information about a State radiation analyst—
(a)the State radiation analyst’s name;
(b)if the State radiation analyst is appointed for a term—the term of the appointment;
(c)any conditions of the State radiation analyst’s appointment.

Part 14 Disclosure of protected information

86Disclosure of protected information

For the Act, section 209(4), the purposes for which protected information may be disclosed by the chief executive are as follows—
(a)for the development of a plan to avoid or limit the impact of an emergency situation on persons, property or the environment;
(b)to enable persons dealing with an emergency situation to know the hazards, or possible hazards, the persons may face in dealing with the emergency situation;
(c)to protect national security, including, for example—
(i)to facilitate the tracking of radiation sources within or outside Australia; and
(ii)to enable State or national alerts, advisory documents and other relevant information to be provided about an incident involving a radiation source; and
(iii)in the case of a security breach relating to a radiation source, to enable a coordinated response to be initiated and implemented; and
(iv)to monitor and evaluate initiatives implemented to ensure the security of radiation sources; and
(v)to help the development, review or improvement of policies, operational guidelines, codes, standards or legislation relating to national security; and
(vi)to develop or implement training programs about the security of radiation sources, including policies, codes, standards or legislation relating to the programs; and
(vii)to undertake or facilitate research about best practice associated with the security of radiation sources.

Part 15 Fees

87Fees—general

The fees payable under the Act are stated in schedule 8.

88Fees—Act, s 51(1)(c)(i)

(1)Subsection (2) applies to an application for a possession licence for the possession of a radioactive substance for a radiation practice.
(2)For the Act, section 51(1)(c)(i), the fee is the total of the following—
(a)an application fee;
(b)a licence fee consisting of—
(i)a base fee; and
(ii)a fee calculated having regard to the number of sealed radioactive substances, or types of unsealed radioactive substances, that are the subject of the application.
(3)Subsection (4) applies to an application for a possession licence for the possession of a radiation apparatus for a radiation practice.
(4)For the Act, section 51(1)(c)(i), the fee is the total of the following—
(a)an application fee;
(b)a licence fee consisting of—
(i)a base fee; and
(ii)a fee calculated having regard to the number of radiation apparatus that are the subject of the application.
(5)Subsection (6) applies to an application for a use licence or transport licence.
(6)For the Act, section 51(1)(c)(i), the fee is the total of the following—
(a)an application fee;
(b)a licence fee.
(7)Subsection (8) applies to an application for an accreditation certificate.
(8)For the Act, section 51(1)(c)(i), the fee is the total of the following—
(a)an application fee;
(b)an accreditation certificate fee.
(9)Subsection (10) applies to an application for a radiation safety officer certificate.
(10)For the Act, section 51(1)(c)(i), the fee is the total of the following—
(a)an application fee;
(b)a radiation safety officer certificate fee.

s 88 amd 2012 SL No. 152 s 14

89Fees—Act, s 79(3)(b)(i)

(1)Subsection (2) applies to an application for the renewal of a possession licence for the possession of a radioactive substance for a radiation practice.
(2)For the Act, section 79(3)(b)(i), the fee is a licence fee consisting of the following—
(a)a base fee;
(b)a fee calculated having regard to the number of sealed radioactive substances, or types of unsealed radioactive substances, that are the subject of the application.
(3)Subsection (4) applies to an application for the renewal of a possession licence for the possession of a radiation apparatus for a radiation practice.
(4)For the Act, section 79(3)(b)(i), the fee is a licence fee consisting of the following—
(a)a base fee;
(b)a fee calculated having regard to the number of radiation apparatus that are the subject of the application.
(5)Subsection (6) applies to an application for the renewal of a use or transport licence.
(6)For the Act, section 79(3)(b)(i), the fee is a licence fee.
(7)Subsection (8) applies to an application for the renewal of an accreditation certificate.
(8)For the Act, section 79(3)(b)(i), the fee is an accreditation certificate fee.
(9)Subsection (10) applies to an application for the renewal of a radiation safety officer certificate.
(10)For the Act, section 79(3)(b)(i), the fee is a radiation safety officer certificate fee.

s 89 amd 2017 SL No. 81 s 16

90Who pays fee for security check or criminal history check—Act, s 103A

The following person must pay the prescribed fee for a security check or criminal history check—
(a)for a check for an individual applicant for a licence—the applicant;
(b)for a check for the nominated person for a corporation that is an applicant for a licence—the corporation;
(c)for a check for a person who is to have access to a security enhanced source under the approved security plan for the source—the possession licensee requesting the check;
(d)for a check for a person who is to have access to a security enhanced source under the approved transport security plan for the transport of the source—the transport security plan holder requesting the check.

91Waiver of fees—general

(1)Subsection (2) applies if—
(a)under the Act, section 220, a person is taken to be the holder of a column 2 licence; and
(b)before the expiry of the licence, the person applies for the same type of licence.
(2)The application fee, payable under this regulation, for the licence is not payable by the person.
(3)Subsection (4) applies if a person—
(a)is required to use a radiation source during the person’s study or training at an educational institution; and
(b)under the Act, the person needs a use licence allowing the use of the source.
(4)The application fee and licence fee, payable under this regulation, for the licence are not payable by the person.
(5)Subsection (6) applies if—
(a)under the Act, section 224(3), a person is taken to be a radiation safety officer for a radiation practice; and
(b)while continuing as a radiation safety officer for the practice, the person applies for a radiation safety officer certificate.
(6)The application fee, payable under this regulation, for the certificate is not payable by the person.
(7)Subsection (8) applies to a use licensee who, under the licence, is allowed to use a radiation source to carry out a diagnostic or therapeutic procedure involving the irradiation of a person.
(8)If the licensee applies for another use licence to carry out a diagnostic or therapeutic procedure involving the irradiation of a person, the application fee, payable under this regulation, for the licence is not payable by the licensee.
(9)The following fees are not payable by the State—
(a)the fees stated in schedule 8, parts 1 and 4;
(b)the fee for approval to dispose;
(c)the fee for approval to acquire;
(d)the fee for approval to relocate.

92Waiver of fees—undergraduates’ professional development year

(1)This section applies to a graduate practitioner who—
(a)undertakes his or her professional development year; and
(b)applies for a use licence to carry out a diagnostic or therapeutic procedure involving the irradiation of another person during the person’s professional development year.
(2)The application fee payable under this regulation for the licence is not payable by the graduate practitioner.
(3)In this section—
accrediting body means the Australian Institute of Radiography ACN 000 084 462 or the Australian and New Zealand Society of Nuclear Medicine Limited ACN 133 630 029.
graduate practitioner means a person who—
(a)is a graduate from an undergraduate medical radiation science degree course accredited by an accrediting body, regardless of the title of the course; or
(b)is assessed by an accrediting body to be the equivalent of a person mentioned in paragraph (a).
professional development year means the period, the equivalent of 48 weeks full-time work, during which a graduate practitioner must work under the guidance of another practitioner before the graduate practitioner is recognised as an accredited practitioner by an accrediting body.

93Waiver of fee—licensee applying for new licences within the transitional period

(1)This section applies if a relevant licensee makes a relevant application and a relevant licence fee becomes payable.
(2)The relevant licence fee, otherwise payable under this regulation, is not payable by the relevant licensee.
(3)In this section—
relevant application means—
(a)an application for a new possession licence under the Act, section 232(4); or
(b)an application for a new use licence under the Act, section 233(2); or
(c)an application for a new transport licence under the Act, section 234(2).
relevant licence fee means—
(a)the application fee for a possession licence—schedule 8, item 1(a); or
(b)the base fee for a possession licence for 1 year or less—schedule 8, item 2(a)(i); or
(c)the application fee for a use or transport licence—schedule 8, item 7; or
(d)the use or transport licence fee for 1 year or less—schedule 8, item 8(a).
relevant licensee means—
(a)a possession licensee to whom the Act, section 232 applies; or
(b)a use licensee to whom the Act, section 233 applies; or
(c)a transport licensee to whom the Act, section 234 applies.

94Refund of fees

(1)The chief executive must as soon as practicable refund the fees, other than the application fee, paid on an application for the grant or renewal of an accreditation certificate, licence or radiation safety officer certificate if—
(a)the chief executive refuses to grant the application; or
(b)the applicant withdraws the application before it is decided.
(2)The chief executive must not refund any of the following fees—
(a)an application by a possession licensee to change the licensee’s approved security plan;
(b)an application for approval of a transport security plan;
(c)an application by a transport security plan holder to change the holder’s approved transport security plan;
(d)an application for approval to acquire;
(e)an application for approval to dispose;
(f)an application for approval to relocate;
(g)an application by the holder of a conditional Act instrument to change the conditions of the instrument imposed by the chief executive;
(h)an application by a possession licensee to change the licensee’s approved radiation safety and protection plan for a radiation practice.

Part 15A [Repealed]

pt 15A hdg ins 2013 SL No. 288 s 5

exp 30 December 2014 (see s 94A)

94A[Repealed]

s 94A ins 2013 SL No. 288 s 5

exp 30 December 2014 (see s 94A)

Part 16 Repeal and transitional provisions

Division 1 Repeal and transitional provision for repeal

pt 16 div 1 hdg ins 2013 SL No. 288 s 6

95Repeal

The Radiation Safety Regulation 1999, SL No. 330 is repealed.

96Transitional provision for Radiation Safety Regulation 2010

(1)In a document, a reference to the repealed Radiation Safety Regulation 1999 may, if the context permits, be taken to be a reference to this regulation.
(2)Without limiting subsection (1), a reference in a document to schedule 3A of the repealed Radiation Safety Regulation 1999 may, if the context permits, be taken to be a reference to schedule 6.

Division 2 Transitional provisions for Radiation Safety Amendment Regulation (No. 1) 2013

pt 16 div 2 hdg ins 2013 SL No. 288 s 7

97Definition for div 2

In this division—
commencement means the commencement of this section.

s 97 ins 2012 SL No. 246 s 8

sub 2013 SL No. 288 s 7

98Application of s 64A

(1)This section applies if a possession licensee, under the licence—
(a)possesses a relevant solarium immediately before the commencement; and
(b)continues to possess the relevant solarium on the commencement.
(2)Section 64A does not apply to the relevant solarium until the earlier of the following—
(a)the licence ends;
(b)31 December 2014.

s 98 ins 2013 SL No. 288 s 7

99Particular solarium continues to be relevant solarium

(1)This section applies to a solarium if, immediately before the commencement, the solarium is a relevant solarium.
(2)Despite schedule 9, definition relevant solarium, the solarium continues to be a relevant solarium after the commencement.

s 99 ins 2013 SL No. 288 s 7

Schedule 1 Radionuclide concentrations and activities

sections 4, 5, 17 and 78

Item

Column 1

Column 2

Column 3

 

Radionuclide

Concentration (Bq/g)

Activity (Bq)

1

Actinium-225

1 x 10+1

1 x 10+4

2

Actinium-227

1 x 10-1

1 x 10+3

3

Actinium-228

1 x 10+1

1 x 10+6

4

Americium-241

1 x 100

1 x 10+4

5

Americium-242

1 x 10+3

1 x 10+6

6

Americium-242m1

1 x 100

1 x 10+4

7

Americium-2431

1 x 100

1 x 10+3

8

Antimony-122

1 x 10+2

1 x 10+4

9

Antimony-124

1 x 10+1

1 x 10+6

10

Antimony-125

1 x 10+2

1 x 10+6

11

Argon-37

1 x 10+6

1 x 10+8

12

Argon-41

1 x 10+2

1 x 10+9

13

Arsenic-73

1 x 10+3

1 x 10+7

14

Arsenic-74

1 x 10+1

1 x 10+6

15

Arsenic-76

1 x 10+2

1 x 10+5

16

Arsenic-77

1 x 10+3

1 x 10+6

17

Astatine-211

1 x 10+3

1 x 10+7

18

Barium-131

1 x 10+2

1 x 10+6

19

Barium-133

1 x 10+2

1 x 10+6

20

Barium-1401

1 x 10+1

1 x 10+5

21

Berkelium-249

1 x 10+3

1 x 10+6

22

Beryllium-7

1 x 10+3

1 x 10+7

23

Bismuth-206

1 x 10+1

1 x 10+5

24

Bismuth-207

1 x 10+1

1 x 10+6

25

Bismuth-210

1 x 10+3

1 x 10+6

26

Bismuth-2121

1 x 10+1

1 x 10+5

27

Bismuth-213

1 x 10+2

1 x 10+6

28

Bromine-75

1 x 10+1

1 x 10+6

29

Bromine-76

1 x 10+1

1 x 10+5

30

Bromine-82

1 x 10+1

1 x 10+6

31

Cadmium-109

1 x 10+4

1 x 10+6

32

Cadmium-115

1 x 10+2

1 x 10+6

33

Cadmium-115m

1 x 10+3

1 x 10+6

34

Caesium-129

1 x 10+2

1 x 10+5

35

Caesium-131

1 x 10+3

1 x 10+6

36

Caesium-132

1 x 10+1

1 x 10+5

37

Caesium-134

1 x 10+1

1 x 10+4

38

Caesium-134m

1 x 10+3

1 x 10+5

39

Caesium-135

1 x 10+4

1 x 10+7

40

Caesium-136

1 x 10+1

1 x 10+5

41

Caesium-1371

1 x 10+1

1 x 10+4

42

Caesium-138

1 x 10+1

1 x 10+4

43

Calcium-47

1 x 10+1

1 x 10+6

44

Calcium-45

1 x 10+4

1 x 10+7

45

Californium-246

1 x 10+3

1 x 10+6

46

Californium-248

1 x 10+1

1 x 10+4

47

Californium-249

1 x 100

1 x 10+3

48

Californium-250

1 x 10+1

1 x 10+4

49

Californium-251

1 x 100

1 x 10+3

50

Californium-252

1 x 10+1

1 x 10+4

51

Californium-253

1 x 10+2

1 x 10+5

52

Californium-254

1 x 100

1 x 10+3

53

Carbon-14

1 x 10+4

1 x 10+7

54

Carbon-11

1 x 10+1

1 x 10+6

55

Cerium-139

1 x 10+2

1 x 10+6

56

Cerium-141

1 x 10+2

1 x 10+7

57

Cerium-143

1 x 10+2

1 x 10+6

58

Cerium-1441

1 x 10+2

1 x 10+5

59

Chlorine-36

1 x 10+4

1 x 10+6

60

Chlorine-38

1 x 10+1

1 x 10+5

61

Chromium-51

1 x 10+3

1 x 10+7

62

Cobalt-57

1 x 10+2

1 x 10+6

63

Cobalt-56

1 x 10+1

1 x 10+5

64

Cobalt-55

1 x 10+1

1 x 10+6

65

Cobalt-62m

1 x 10+1

1 x 10+5

66

Cobalt-60m

1 x 10+3

1 x 10+6

67

Cobalt-60

1 x 10+1

1 x 10+5

68

Cobalt-58

1 x 10+1

1 x 10+6

69

Cobalt-61

1 x 10+2

1 x 10+6

70

Cobalt-58m

1 x 10+4

1 x 10+7

71

Copper-64

1 x 10+2

1 x 10+6

72

Copper-67

1 x 10+2

1 x 10+6

73

Curium-242

1 x 10+2

1 x 10+5

74

Curium-243

1 x 100

1 x 10+4

75

Curium-244

1 x 10+1

1 x 10+4

76

Curium-245

1 x 100

1 x 10+3

77

Curium-246

1 x 100

1 x 10+3

78

Curium-247

1 x 100

1 x 10+4

79

Curium-248

1 x 100

1 x 10+3

80

Dysprosium-165

1 x 10+3

1 x 10+6

81

Dysprosium-166

1 x 10+3

1 x 10+6

82

Einsteinium-253

1 x 10+2

1 x 10+5

83

Einsteinium-254

1 x 10+1

1 x 10+4

84

Einsteinium-254m

1 x 10+2

1 x 10+6

85

Erbium-161

1 x 10+1

1 x 10+6

86

Erbium-169

1 x 10+4

1 x 10+7

87

Erbium-171

1 x 10+2

1 x 10+6

88

Europium-152

1 x 10+1

1 x 10+6

89

Europium-152m

1 x 10+2

1 x 10+6

90

Europium-154

1 x 10+1

1 x 10+6

91

Europium-155

1 x 10+2

1 x 10+7

92

Fermium-254

1 x 10+4

1 x 10+7

93

Fermium-255

1 x 10+3

1 x 10+6

94

Fluorine-18

1 x 10+1

1 x 10+6

95

Gadolinium-153

1 x 10+2

1 x 10+7

96

Gadolinium-159

1 x 10+3

1 x 10+6

97

Gallium-67

1 x 10+2

1 x 10+6

98

Gallium-72

1 x 10+1

1 x 10+5

99

Germanium-71

1 x 10+4

1 x 10+8

100

Germanium-68

1 x 10+1

1 x 10+5

101

Gold-198

1 x 10+2

1 x 10+6

102

Gold-199

1 x 10+2

1 x 10+6

103

Hafnium-181

1 x 10+1

1 x 10+6

104

Holmium-166

1 x 10+3

1 x 10+5

105

Holmium-166m

1 x 10+1

1 x 10+6

106

Hydrogen-3

1 x 10+6

1 x 10+9

107

Indium-111

1 x 10+2

1 x 10+6

108

Indium-113m

1 x 10+2

1 x 10+6

109

Indium-114m

1 x 10+2

1 x 10+6

110

Indium-115m

1 x 10+2

1 x 10+6

111

Iodine-123

1 x 10+2

1 x 10+7

112

Iodine-124

1 x 10+1

1 x 10+6

113

Iodine-125

1 x 10+3

1 x 10+6

114

Iodine-126

1 x 10+2

1 x 10+6

115

Iodine-129

1 x 10+2

1 x 10+5

116

Iodine-130

1 x 10+1

1 x 10+6

117

Iodine-131

1 x 10+2

1 x 10+6

118

Iodine-132

1 x 10+1

1 x 10+5

119

Iodine-133

1 x 10+1

1 x 10+6

120

Iodine-134

1 x 10+1

1 x 10+5

121

Iodine-135

1 x 10+1

1 x 10+6

122

Iridium-190

1 x 10+1

1 x 10+6

123

Iridium-192

1 x 10+1

1 x 10+4

124

Iridium-194

1 x 10+2

1 x 10+5

125

Iron-52

1 x 10+1

1 x 10+6

126

Iron-55

1 x 10+4

1 x 10+6

127

Iron-59

1 x 10+1

1 x 10+6

128

Krypton-74

1 x 10+2

1 x 10+9

129

Krypton-76

1 x 10+2

1 x 10+9

130

Krypton-77

1 x 10+2

1 x 10+9

131

Krypton-79

1 x 10+3

1 x 10+5

132

Krypton-81

1 x 10+4

1 x 10+7

133

Krypton-83m

1 x 10+5

1 x 10+12

134

Krypton-85

1 x 10+5

1 x 10+4

135

Krypton-85m

1 x 10+3

1 x 10+10

136

Krypton-87

1 x 10+2

1 x 10+9

137

Krypton-88

1 x 10+2

1 x 10+9

138

Lanthanum-140

1 x 10+1

1 x 10+5

139

Lead-203

1 x 10+2

1 x 10+6

140

Lead-2101

1 x 10+1

1 x 10+4

141

Lead-2121

1 x 10+1

1 x 10+5

142

Lutetium-177

1 x 10+3

1 x 10+7

143

Magnesium-28

1 x 10+1

1 x 10+5

144

Manganese-51

1 x 10+1

1 x 10+5

145

Manganese-53

1 x 10+4

1 x 10+9

146

Manganese-52m

1 x 10+1

1 x 10+5

147

Manganese-52

1 x 10+1

1 x 10+5

148

Manganese-56

1 x 10+1

1 x 10+5

149

Manganese-54

1 x 10+1

1 x 10+6

150

Mercury-195m

1 x 10+2

1 x 10+6

151

Mercury-197

1 x 10+2

1 x 10+7

152

Mercury-197m

1 x 10+2

1 x 10+6

153

Mercury-203

1 x 10+2

1 x 10+5

154

Molybdenum-101

1 x 10+1

1 x 10+6

155

Molybdenum-90

1 x 10+1

1 x 10+6

156

Molybdenum-93

1 x 10+3

1 x 10+8

157

Molybdenum-99

1 x 10+2

1 x 10+6

158

Neodymium-147

1 x 10+2

1 x 10+6

159

Neodymium-149

1 x 10+2

1 x 10+6

160

Neptunium-2371

1 x 100

1 x 10+3

161

Neptunium-239

1 x 10+2

1 x 10+7

162

Neptunium-240

1 x 10+1

1 x 10+6

163

Nickel-63

1 x 10+5

1 x 10+8

164

Nickel-59

1 x 10+4

1 x 10+8

165

Nickel-65

1 x 10+1

1 x 10+6

166

Niobium-93m

1 x 10+4

1 x 10+7

167

Niobium-94

1 x 10+1

1 x 10+6

168

Niobium-95

1 x 10+1

1 x 10+6

169

Niobium-97

1 x 10+1

1 x 10+6

170

Niobium-98

1 x 10+1

1 x 10+5

171

Nitrogen-13

1 x 10+2

1 x 10+9

172

Osmium-185

1 x 10+1

1 x 10+6

173

Osmium-191

1 x 10+2

1 x 10+7

174

Osmium-191m

1 x 10+3

1 x 10+7

175

Osmium-193

1 x 10+2

1 x 10+6

176

Oxygen-15

1 x 10+2

1 x 10+9

177

Palladium-103

1 x 10+3

1 x 10+8

178

Palladium-109

1 x 10+3

1 x 10+6

179

Phosphorus-32

1 x 10+3

1 x 10+5

180

Phosphorus-33

1 x 10+5

1 x 10+8

181

Platinum-191

1 x 10+2

1 x 10+6

182

Platinum-193m

1 x 10+3

1 x 10+7

183

Platinum-197

1 x 10+3

1 x 10+6

184

Platinum-197m

1 x 10+2

1 x 10+6

185

Plutonium-234

1 x 10+2

1 x 10+7

186

Plutonium-235

1 x 10+2

1 x 10+7

187

Plutonium-236

1 x 10+1

1 x 10+4

188

Plutonium-237

1 x 10+3

1 x 10+7

189

Plutonium-238

1 x 100

1 x 10+4

190

Plutonium-239

1 x 100

1 x 10+4

191

Plutonium-240

1 x 100

1 x 10+3

192

Plutonium-241

1 x 10+2

1 x 10+5

193

Plutonium-242

1 x 100

1 x 10+4

194

Plutonium-243

1 x 10+3

1 x 10+7

195

Plutonium-244

1 x 100

1 x 10+4

196

Polonium-203

1 x 10+1

1 x 10+6

197

Polonium-205

1 x 10+1

1 x 10+6

198

Polonium-207

1 x 10+1

1 x 10+6

199

Polonium-210

1 x 10+1

1 x 10+4

200

Potassium-43

1 x 10+1

1 x 10+6

201

Potassium-42

1 x 10+2

1 x 10+6

202

Potassium-40

1 x 10+2

1 x 10+6

203

Praseodymium-142

1 x 10+2

1 x 10+5

204

Praseodymium-143

1 x 10+4

1 x 10+6

205

Promethium-147

1 x 10+4

1 x 10+7

206

Promethium-149

1 x 10+3

1 x 10+6

207

Protactinium-230

1 x 10+1

1 x 10+6

208

Protactinium-231

1 x 100

1 x 10+3

209

Protactinium-233

1 x 10+2

1 x 10+7

210

Radium-2231

1 x 10+2

1 x 10+5

211

Radium-2241

1 x 10+1

1 x 10+5

212

Radium-225

1 x 10+2

1 x 10+5

213

Radium-2261

1 x 10+1

1 x 10+4

214

Radium-227

1 x 10+2

1 x 10+6

215

Radium-2281

1 x 10+1

1 x 10+5

216

Radon-2201

1 x 10+4

1 x 10+7

217

Radon-2221

1 x 10+1

1 x 10+8

218

Rhenium-186

1 x 10+3

1 x 10+6

219

Rhenium-188

1 x 10+2

1 x 10+5

220

Rhodium-103m

1 x 10+4

1 x 10+8

221

Rhodium-105

1 x 10+2

1 x 10+7

222

Rubidium-81

1 x 10+1

1 x 10+6

223

Rubidium-86

1 x 10+2

1 x 10+5

224

Ruthenium-103

1 x 10+2

1 x 10+6

225

Ruthenium-105

1 x 10+1

1 x 10+6

226

Ruthenium-1061

1 x 10+2

1 x 10+5

227

Ruthenium-97

1 x 10+2

1 x 10+7

228

Samarium-147

1 x 10+1

1 x 10+4

229

Samarium-151

1 x 10+4

1 x 10+8

230

Samarium-153

1 x 10+2

1 x 10+6

231

Scandium-44

1 x 10+1

1 x 10+4

232

Scandium-48

1 x 10+1

1 x 10+5

233

Scandium-46

1 x 10+1

1 x 10+6

234

Scandium-47

1 x 10+2

1 x 10+6

235

Selenium-72

1 x 10+1

1 x 10+4

236

Selenium-73

1 x 10+1

1 x 10+6

237

Selenium-75

1 x 10+2

1 x 10+6

238

Silicon-31

1 x 10+3

1 x 10+6

239

Silicon-32

1 x 10+1

1 x 10+4

240

Silver-105

1 x 10+2

1 x 10+6

241

Silver-108m

1 x 10+1

1 x 10+6

242

Silver-110m

1 x 10+1

1 x 10+6

243

Silver-111

1 x 10+3

1 x 10+6

244

Sodium-22

1 x 10+1

1 x 10+6

245

Sodium-24

1 x 10+1

1 x 10+5

246

Strontium-82

1 x 10+1

1 x 10+4

247

Strontium-85

1 x 10+2

1 x 10+6

248

Strontium-85m

1 x 10+2

1 x 10+7

249

Strontium-87m

1 x 10+2

1 x 10+6

250

Strontium-89

1 x 10+3

1 x 10+6

251

Strontium-90l

1 x 10+2

1 x 10+4

252

Strontium-91

1 x 10+1

1 x 10+5

253

Strontium-92

1 x 10+1

1 x 10+6

254

Sulphur-35

1 x 10+5

1 x 10+8

255

Tantalum-182

1 x 10+1

1 x 10+4

256

Technetium-95m

1 x 10+1

1 x 10+6

257

Technetium-96

1 x 10+1

1 x 10+6

258

Technetium-96m

1 x 10+3

1 x 10+7

259

Technetium-97

1 x 10+3

1 x 10+8

260

Technetium-97m

1 x 10+3

1 x 10+7

261

Technetium-99

1 x 10+4

1 x 10+7

262

Technetium-99m

1 x 10+2

1 x 10+7

263

Tellurium-123m

1 x 10+2

1 x 10+7

264

Tellurium-125m

1 x 10+3

1 x 10+7

265

Tellurium-127

1 x 10+3

1 x 10+6

266

Tellurium-127m

1 x 10+3

1 x 10+7

267

Tellurium-129

1 x 10+2

1 x 10+6

268

Tellurium-129m

1 x 10+3

1 x 10+6

269

Tellurium-131

1 x 10+2

1 x 10+5

270

Tellurium-131m

1 x 10+1

1 x 10+6

271

Tellurium-132

1 x 10+2

1 x 10+7

272

Tellurium-133

1 x 10+1

1 x 10+5

273

Tellurium-133m

1 x 10+1

1 x 10+5

274

Tellurium-134

1 x 10+1

1 x 10+6

275

Terbium-160

1 x 10+1

1 x 10+6

276

Thallium-200

1 x 10+1

1 x 10+6

277

Thallium-201

1 x 10+2

1 x 10+6

278

Thallium-202

1 x 10+2

1 x 10+6

279

Thallium-204

1 x 10+4

1 x 10+4

280

Thorium-2261

1 x 10+3

1 x 10+7

281

Thorium-227

1 x 10+1

1 x 10+4

282

Thorium-2281

1 x 100

1 x 10+4

283

Thorium-2291

1 x 100

1 x 10+3

284

Thorium-230

1 x 100

1 x 10+4

285

Thorium-231

1 x 10+3

1 x 10+7

286

Thorium-2341

1 x 10+3

1 x 10+5

287

Thorium-nat including thorium-232

1 x 100

1 x 10+3

288

Thulium-170

1 x 10+3

1 x 10+6

289

Thulium-171

1 x 10+4

1 x 10+8

290

Tin-113

1 x 10+3

1 x 10+7

291

Tin-117m

1 x 10+2

1 x 10+6

292

Tin-121

1 x 10+5

1 x 10+7

293

Tin-125

1 x 10+2

1 x 10+5

294

Tungsten-181

1 x 10+3

1 x 10+7

295

Tungsten-185

1 x 10+4

1 x 10+7

296

Tungsten-187

1 x 10+2

1 x 10+6

297

Tungsten-188

1 x 10+2

1 x 10+5

298

Uranium-2401

1 x 10+1

1 x 10+6

299

Uranium-2301

1 x 10+1

1 x 10+5

300

Uranium-231

1 x 10+2

1 x 10+7

301

Uranium-2321

1 x 100

1 x 10+3

302

Uranium-233

1 x 10+1

1 x 10+4

303

Uranium-234

1 x 10+1

1 x 10+4

304

Uranium-2351

1 x 10+1

1 x 10+4

305

Uranium-236

1 x 10+1

1 x 10+4

306

Uranium-237

1 x 10+2

1 x 10+6

307

Uranium-2381

1 x 10+1

1 x 10+4

308

Uranium-239

1 x 10+2

1 x 10+6

309

Uranium-240

1 x 10+3

1 x 10+7

310

Uranium-nat

1 x 100

1 x 10+3

311

Vanadium-48

1 x 10+1

1 x 10+5

312

Xenon-131m

1 x 10+4

1 x 10+4

313

Xenon-133

1 x 10+3

1 x 10+4

314

Xenon-135

1 x 10+3

1 x 10+10

315

Ytterbium-169

1 x 10+2

1 x 10+7

316

Ytterbium-175

1 x 10+3

1 x 10+7

317

Yttrium-88

1 x 10+1

1 x 10+6

318

Yttrium-90

1 x 10+3

1 x 10+5

319

Yttrium-91

1 x 10+3

1 x 10+6

320

Yttrium-91m

1 x 10+2

1 x 10+6

321

Yttrium-92

1 x 10+2

1 x 10+5

322

Yttrium-93

1 x 10+2

1 x 10+5

323

Zinc-69m

1 x 10+2

1 x 10+6

324

Zinc-65

1 x 10+1

1 x 10+6

325

Zinc-69

1 x 10+4

1 x 10+6

326

Zirconium-931

1 x 10+3

1 x 10+7

327

Zirconium-95

1 x 10+1

1 x 10+6

328

Zirconium-971

1 x 10+1

1 x 10+5

329

alpha-emitting radionuclide not mentioned in another item

1 x 100

1 x 10+3

330

radionuclide that is not alpha-emitting and not mentioned in another item

1 x 10+1

1 x 10+4

The superscript ‘1’ immediately following an item in column 1 indicates that the item’s concentration and activity are the concentration and activity of the parent radionuclide and its progeny when in secular equilibrium.

Schedule 2 Security categorisation of a radiation source or an aggregation of radiation sources

section 8

Part 1 Security categories

Security category

Activity ratio

1

Equal to or greater than 1,000

2

Less than 1,000 but greater than or equal to 10

3

Less than 10 but greater than or equal to 1

4

Less than 1 but greater than or equal to 0.01

5

Less than 0.01

Part 2 Radionuclide activity values

Item

Column 1

Column 2

 

Radionuclide

Activity value (GBq)

1

Americium-241

60

2

Americium-241/Beryllium

60

3

Cadmium-109

2 x 104

4

Caesium-137

100

5

Californium-252

20

6

Cobalt-57

700

7

Cobalt-60

30

8

Curium-244

50

9

Gadolinium-153

1 x 103

10

Germanium-68

700

11

Gold-198

200

12

Iodine-125

200

13

Iodine-131

200

14

Iridium-192

80

15

Iron-55

8 x 105

16

Krypton-85

3 x 104

17

Molybdenum-99

300

18

Nickel-63

6 x 104

19

Palladium-103

9 x 104

20

Phosphorus-32

1 x 104

21

Plutonium-238

60

22

Plutonium-239/Beryllium

60

23

Polonium-210

60

24

Promethium-147

4 x 104

25

Radium-226

40

26

Ruthenium-106 (Rhodium-106)

300

27

Selenium-75

200

28

Strontium-90 (Yttrium-90)

1 x 103

29

Technetium-99m

700

30

Thallium-204

2 x 104

31

Thulium

2 x 104

32

Tritium (H-3)

2 x 106

33

Ytterbium-169

300

34

All other radioisotopes

20

sch 2 amd 2012 SL No. 246 s 9

Schedule 3 Disposal of radioactive material—radionuclide concentrations

sections 15 and 16

Item

Column 1

Column 2

Column 3

Column 4

 

Radionuclide

Release to air concentration (Bq/m3)

Release to water

concentration

(Bq/m3)

Release to sewerage system concentration (Bq/m3)

1

Actinium-225

3.77 x 10-3

2.85 x 10+4

5.71 x 10+4

2

Actinium-227

4.73 x 10-5

6.23 x 10+2

1.25 x 10+3

3

Actinium-228

1.03 x 100

1.59 x 10+6

3.19 x 10+6

4

Americium-241

7.64 x 10-4

3.42 x 10+3

6.85 x 10+3

5

Americium-242

1.86 x 100

2.28 x 10+6

4.57 x 10+6

6

Americium-242m1

8.51 x 10-4

3.60 x 10+3

7.21 x 10+3

7

Americium-2431

7.64 x 10-4

3.42 x 10+3

6.85 x 10+3

8

Antimony-122

2.48 x 10+1

4.03 x 10+5

8.06 x 10+5

9

Antimony-124

4.88 x 100

2.74 x 10+5

5.48 x 10+5

10

Antimony-125

6.62 x 100

6.23 x 10+5

1.25 x 10+6

11

Argon-37

3.34 x 10+8

-

-

12

Argon-41

2.58 x 10+2

-

-

13

Arsenic-73

3.20 x 10+1

2.63 x 10+6

5.27 x 10+6

14

Arsenic-74

1.42 x 10+1

5.27 x 10+5

1.05 x 10+6

15

Arsenic-76

3.24 x 10+1

4.28 x 10+5

8.56 x 10+5

16

Arsenic-77

7.09 x 10+1

1.71 x 10+6

3.42 x 10+6

17

Astatine-211

2.71 x 10-1

6.23 x 10+4

1.25 x 10+5

18

Barium-131

8.51 x 10+1

1.52 x 10+6

3.04 x 10+6

19

Barium-133

1.65 x 10+1

6.85 x 10+5

1.37 x 10+6

20

Barium-1401

1.86 x 10+1

2.74 x 10+5

5.48 x 10+5

21

Berkelium-249

1.99 x 10-1

7.06 x 10+5

1.41 x 10+6

22

Beryllium-7

5.73 x 10+2

2.45 x 10+7

4.89 x 10+7

23

Bismuth-206

1.42 x 10+1

3.60 x 10+5

7.21 x 10+5

24

Bismuth-207

5.73 x 100

5.27 x 10+5

1.05 x 10+6

25

Bismuth-210

3.55 x 10-1

5.27 x 10+5

1.05 x 10+6

26

Bismuth-2121

7.64 x 10-1

2.63 x 10+6

5.27 x 10+6

27

Bismuth-213

7.26 x 10-1

3.42 x 10+6

6.85 x 10+6

28

Bromine-75

3.50 x 10+2

8.67 x 10+6

1.73 x 10+7

29

Bromine-76

5.13 x 10+1

1.49 x 10+6

2.98 x 10+6

30

Bromine-82

3.38 x 10+1

1.27 x 10+6

2.54 x 10+6

31

Cadmium-109

3.10 x 100

3.42 x 10+5

6.85 x 10+5

32

Cadmium-115

2.29 x 10+1

4.89 x 10+5

9.78 x 10+5

33

Cadmium-115m

4.08 x 100

2.08 x 10+5

4.15 x 10+5

34

Caesium-129

3.68 x 10+2

1.14 x 10+7

2.28 x 10+7

35

Caesium-131

6.62 x 10+2

1.18 x 10+7

2.36 x 10+7

36

Caesium-132

7.84 x 10+1

1.37 x 10+6

2.74 x 10+6

37

Caesium-134

3.10 x 100

3.60 x 10+4

7.21 x 10+4

38

Caesium-134m

1.15 x 10+3

3.42 x 10+7

6.85 x 10+7

39

Caesium-135

3.01 x 10+1

3.42 x 10+5

6.85 x 10+5

40

Caesium-136

1.57 x 10+1

2.28 x 10+5

4.57 x 10+5

41

Caesium-1371

4.44 x 100

5.27 x 10+4

1.05 x 10+5

42

Caesium-138

6.47 x 10+2

7.44 x 10+6

1.49 x 10+7

43

Calcium-45

1.10 x 10+1

9.01 x 10+5

1.80 x 10+6

44

Calcium-47

1.42 x 10+1

4.28 x 10+5

8.56 x 10+5

45

Californium-246

7.09 x 10-2

2.08 x 10+5

4.15 x 10+5

46

Californium-248

3.63 x 10-3

2.45 x 10+4

4.89 x 10+4

47

Californium-249

4.51 x 10-4

1.96 x 10+3

3.91 x 10+3

48

Californium-250

9.31 x 10-4

4.28 x 10+3

8.56 x 10+3

49

Californium-251

4.44 x 10-4

1.90 x 10+3

3.81 x 10+3

50

Californium-252

1.65 x 10-3

7.61 x 10+3

1.52 x 10+4

51

Californium-253

2.48 x 10-2

4.89 x 10+5

9.78 x 10+5

52

Californium-254

8.05 x 10-4

1.71 x 10+3

3.42 x 10+3

53

Carbon-11

9.31 x 10+3

2.85 x 10+7

5.71 x 10+7

54

Carbon-14

5.13 x 10+1

1.18 x 10+6

2.36 x 10+6

55

Cerium-139

1.65 x 10+1

2.63 x 10+6

5.27 x 10+6

56

Cerium-141

8.27 x 100

9.65 x 10+5

1.93 x 10+6

57

Cerium-143

2.98 x 10+1

6.23 x 10+5

1.25 x 10+6

58

Cerium-1441

6.08 x 10-1

1.32 x 10+5

2.63 x 10+5

59

Chlorine-36

4.32 x 100

7.36 x 10+5

1.47 x 10+6

60

Chlorine-38

4.08 x 10+2

5.71 x 10+6

1.14 x 10+7

61

Chromium-51

8.27 x 10+2

1.80 x 10+7

3.60 x 10+7

62

Cobalt-55

3.59 x 10+1

6.23 x 10+5

1.25 x 10+6

63

Cobalt-56

4.73 x 100

2.74 x 10+5

5.48 x 10+5

64

Cobalt-57

3.17 x 10+1

3.26 x 10+6

6.52 x 10+6

65

Cobalt-58

1.49 x 10+1

9.26 x 10+5

1.85 x 10+6

66

Cobalt-58m

1.75 x 10+3

2.85 x 10+7

5.71 x 10+7

67

Cobalt-60

1.03 x 100

2.01 x 10+5

4.03 x 10+5

68

Cobalt-60m

2.29 x 10+4

4.03 x 10+8

8.06 x 10+8

69

Cobalt-61

3.97 x 10+2

9.26 x 10+6

1.85 x 10+7

70

Cobalt-62m

8.05 x 10+2

1.46 x 10+7

2.91 x 10+7

71

Copper-64

1.99 x 10+2

5.71 x 10+6

1.14 x 10+7

72

Copper-67

5.13 x 10+1

2.01 x 10+6

4.03 x 10+6

73

Curium-242

6.20 x 10-3

5.71 x 10+4

1.14 x 10+5

74

Curium-243

1.03 x 10-3

4.57 x 10+3

9.13 x 10+3

75

Curium-244

1.19 x 10-3

5.71 x 10+3

1.14 x 10+4

76

Curium-245

7.44 x 10-4

3.26 x 10+3

6.52 x 10+3

77

Curium-246

7.44 x 10-4

3.26 x 10+3

6.52 x 10+3

78

Curium-247

8.27 x 10-4

3.60 x 10+3

7.21 x 10+3

79

Curium-248

2.13 x 10-4

8.90 x10+2

1.78 x 10+3

80

Dysprosium-165

3.42 x 10+2

6.23 x 10+6

1.25 x 10+7

81

Dysprosium-166

1.65 x 10+1

4.28 x 10+5

8.56 x 10+5

82

Einsteinium-253

1.19 x 10-2

1.12 x 10+5

2.25 x 10+5

83

Einsteinium-254

3.72 x 10-3

2.45 x 10+4

4.89 x 10+4

84

Einsteinium-254m

6.77 x 10-2

1.63 x 10+5

3.26 x 10+5

85

Erbium-161

3.50 x 10+2

8.56 x 10+6

1.71 x 10+7

86

Erbium-169

3.04 x 10+1

1.85 x 10+6

3.70 x 10+6

87

Erbium-171

9.93 x 10+1

1.90 x 10+6

3.81 x 10+6

88

Europium-152

7.64 x 10-1

4.89 x 10+5

9.78 x 10+5

89

Europium-152m

9.31 x 10+1

1.37 x 10+6

2.74 x 10+6

90

Europium-154

5.96 x 10-1

3.42 x 10+5

6.85 x 10+5

91

Europium-155

4.58 x 100

2.14 x 10+6

4.28 x 10+6

92

Fermium-254

3.87 x 10-1

1.56 x 10+6

3.11 x 10+6

93

Fermium-255

1.15 x 10-1

2.74 x 10+5

5.48 x 10+5

94

Fluorine-18

3.20 x 10+2

1.4 x 10+7

2.8 x 10+7

95

Gadolinium-153

1.19 x 10+1

2.54 x 10+6

5.07 x 10+6

96

Gadolinium-159

7.64 x 10+1

1.40 x 10+6

2.80 x 10+6

97

Gallium-67

1.06 x 10+2

3.60 x 10+6

7.21 x 10+6

98

Gallium-72

3.55 x 10+1

6.23 x 10+5

1.25 x 10+6

99

Germanium-68

2.29 x 100

5.27 x 10+5

1.05 x 10+6

100

Germanium-71

2.71 x 10+3

5.71 x 10+7

1.14 x 10+8

101

Gold-198

2.71 x 10+1

6.85 x 10+5

1.37 x 10+6

102

Gold-199

3.92 x 10+1

1.56 x 10+6

3.11 x 10+6

103

Hafnium-181

6.34 x 100

6.23 x 10+5

1.25 x 10+6

104

Holmium-166

3.59 x 10+1

4.89 x 10+5

9.78 x 10+5

105

Holmium-166m

2.71 x 10-1

3.42 x 10+5

6.84 x 10+5

106

Hydrogen-3

1.65 x 10+7

3.81 x 10+7

7.61 x 10+7

107

Indium-111

9.61 x 10+1

2.36 x 10+6

4.72 x 10+6

108

Indium-113m

9.31 x 10+2

2.45 x 10+7

4.89 x 10+7

109

Indium-114m

2.71 x 100

1.67 x 10+5

3.34 x 10+5

110

Indium-115m

3.42 x 10+2

7.96 x 10+6

1.59 x 10+7

111

Iodine-123

2.71 x 10+2

3.26 x 10+6

6.52 x 10+6

112

Iodine-124

4.73 x 100

5.27 x 10+4

1.05 x 10+5

113

Iodine-125

4.08 x 100

4.57 x 10+4

9.13 x 10+4

114

Iodine-126

2.13 x 100

2.36 x 10+4

4.72 x 10+4

115

Iodine-129

5.84 x 10-1

6.23 x 10+3

1.25 x 10+4

116

Iodine-130

3.10 x 10+1

3.42 x 10+5

6.85 x 10+5

117

Iodine-131

2.71 x 100

3.11 x 10+4

6.23 x 10+4

118

Iodine-132

1.49 x 10+2

2.36 x 10+6

4.72 x 10+6

119

Iodine-133

1.42 x 10+1

1.59 x 10+5

3.19 x 10+5

120

Iodine-134

3.77 x 10+2

6.23 x 10+6

1.25 x 10+7

121

Iodine-135

6.47 x 10+1

7.36 x 10+5

1.47 x 10+6

122

Iridium-190

1.19 x 10+1

5.71 x 10+5

1.14 x 10+6

123

Iridium-192

4.80 x 100

4.89 x 10+5

9.78 x 10+5

124

Iridium-194

3.97 x 10+1

5.27 x 10+5

1.05 x 10+6

125

Iron-52

3.13 x 10+1

4.89 x 10+5

9.78 x 10+5

126

Iron-55

3.24 x 10+1

2.08 x 10+6

4.15 x 10+6

127

Iron-59

8.51 x 100

3.81 x 10+5

7.61 x 10+5

128

Krypton-74

-

-

-

129

Krypton-76

8.56 x 10+2

-

-

130

Krypton-77

3.51 x 10+2

-

-

131

Krypton-79

1.41 x 10+3

-

-

132

Krypton-81

6.52 x 10+4

-

-

133

Krypton-83m

6.52 x 10+6

-

-

134

Krypton-85

6.23 x 10+4

-

-

135

Krypton-85m

2.32 x 10+3

-

-

136

Krypton-87

4.03 x 10+2

-

-

137

Krypton-88

1.63 x 10+2

-

-

138

Lanthanum-140

1.99 x 10+1

3.42 x 10+5

6.85 x 10+5

139

Lead-203

1.86 x 10+2

2.85 x 10+6

5.71 x 10+6

140

Lead-2101

2.71 x 10-2

1.01 x 10+3

2.01 x 10+3

141

Lead-2121

9.02 x 10-1

1.16 x 10+5

2.32 x 10+5

142

Lutetium-177

2.71 x 10+1

1.29 x 10+6

2.58 x 10+6

143

Magnesium-28

1.75 x 10+1

3.11 x 10+5

6.23 x 10+5

144

Manganese-51

4.38 x 10+2

7.36 x 10+6

1.47 x 10+7

145

Manganese-52

1.65 x 10+1

3.81 x 10+5

7.61 x 10+5

146

Manganese-52m

5.96 x 10+2

9.93 x 10+6

1.99 x 10+7

147

Manganese-53

5.73 x 10+2

2.28 x 10+7

4.57 x 10+7

148

Manganese-54

1.99 x 10+1

9.65 x 10+5

1.93 x 10+6

149

Manganese-56

1.49 x 10+2

2.74 x 10+6

5.48 x 10+6

150

Mercury-195m

4.58 x 10+1

1.22 x 10+6

2.45 x 10+6

151

Mercury-197

1.03 x 10+2

2.98 x 10+6

5.96 x 10+6

152

Mercury-197m

4.51 x 10+1

1.46 x 10+6

2.91 x 10+6

153

Mercury-203

1.29 x 10+1

3.60 x 10+5

7.21 x 10+5

154

Molybdenum-101

6.62 x 10+2

1.63 x 10+7

3.26 x 10+7

155

Molybdenum-90

5.32 x 10+1

1.10 x 10+6

2.21 x 10+6

156

Molybdenum-93

1.35 x 10+1

2.63 x 10+5

5.27 x 10+5

157

Molybdenum-99

2.71 x 10+1

5.71 x 10+5

1.14 x 10+6

158

Neodymium-147

1.29 x 10+1

6.23 x 10+5

1.25 x 10+6

159

Neodymium-149

2.29 x 10+2

5.71 x 10+6

1.14 x 10+7

160

Neptunium-2371

1.42 x 10-3

6.23 x 10+3

1.25 x 10+4

161

Neptunium-239

2.71 x 10+1

8.56 x 10+5

1.71 x 10+6

162

Neptunium-240

2.29 x 10+2

8.35 x 10+6

1.67 x 10+7

163

Nickel-59

1.35 x 10+2

1.09 x 10+7

2.17 x 10+7

164

Nickel-63

5.73 x 10+1

4.57 x 10+6

9.13 x 10+6

165

Nickel-65

2.29 x 10+2

3.81 x 10+6

7.61 x 10+6

166

Niobium-93m

3.46 x 10+1

5.71 x 10+6

1.14 x 10+7

167

Niobium-94

6.62 x 10-1

4.03 x 10+5

8.06 x 10+5

168

Niobium-95

1.86 x 10+1

1.18 x 10+6

2.36 x 10+6

169

Niobium-97

4.14 x 10+2

1.01 x 10+7

2.01 x 10+7

170

Niobium-98

3.01 x 10+2

6.23 x 10+6

1.25 x 10+7

171

Nitrogen-131

-

-

-

172

Osmium-185

1.99 x 10+1

1.34 x 10+6

2.69 x 10+6

173

Osmium-191

1.65 x 10+1

1.20 x 10+6

2.40 x 10+6

174

Osmium-191m

1.99 x 10+2

7.13 x 10+6

1.43 x 10+7

175

Osmium-193

4.38 x 10+1

8.46 x 10+5

1.69 x 10+6

176

Oxygen-15

-

-

-

177

Palladium-103

7.44 x 10+1

3.60 x 10+6

7.21 x 10+6

178

Palladium-109

5.96 x 10+1

1.25 x 10+6

2.49 x 10+6

179

Phosphorus-32

9.31 x 100

2.85 x 10+5

5.71 x 10+5

180

Phosphorus-33

2.13 x 10+1

2.85 x 10+6

5.71 x 10+6

181

Platinum-191

1.57 x 10+2

2.01 x 10+6

4.03 x 10+6

182

Platinum-193m

1.42 x 10+2

1.52 x 10+6

3.04 x 10+6

183

Platinum-197

1.86 x 10+2

1.71 x 10+6

3.42 x 10+6

184

Platinum-197m

6.93 x 10+2

8.15 x 10+6

1.63 x 10+7

185

Plutonium-234

1.35 x 100

4.28 x 10+6

8.56 x 10+6

186

Plutonium-235

1.15 x 10+4

3.26 x 10+8

6.52 x 10+8

187

Plutonium-236

1.65 x 10-3

7.96 x 10+3

1.59 x 10+4

188

Plutonium-237

8.27 x 10+1

6.85 x 10+6

1.37 x 10+7

189

Plutonium-238

6.93 x 10-4

2.98 x 10+3

5.96 x 10+3

190

Plutonium-239

6.34 x 10-4

2.74 x 10+3

5.48 x 10+3

191

Plutonium-240

6.34 x 10-4

2.74 x 10+3

5.48 x 10+3

192

Plutonium-241

3.50 x 10-2

1.46 x 10+5

2.91 x 10+5

193

Plutonium-242

6.77 x 10-4

2.85 x 10+3

5.71 x 10+3

194

Plutonium-243

2.71 x 10+2

8.06 x 10+6

1.61 x 10+7

195

Plutonium-244

6.77 x 10-4

2.85 x 10+3

5.71 x 10+3

196

Polonium-203

4.88 x 10+2

1.32 x 10+7

2.63 x 10+7

197

Polonium-205

3.35 x 10+2

1.16 x 10+7

2.32 x 10+7

198

Polonium-207

1.99 x 10+2

4.89 x 10+6

9.78 x 10+6

199

Polonium-210

9.93 x 10-3

2.85 x 10+3

5.71 x 10+3

200

Potassium-40

9.93 x 100

1.10 x 10+5

2.21 x 10+5

201

Potassium-42

1.49 x 10+2

1.59 x 10+6

3.19 x 10+6

202

Potassium-43

1.15 x 10+2

2.74 x 10+6

5.48 x 10+6

203

Praseodymium-142

4.02 x 10+1

5.27 x 10+5

1.05 x 10+6

204

Praseodymium-143

1.29 x 10+1

5.71 x 10+5

1.14 x 10+6

205

Promethium-147

6.34 x 100

2.63 x 10+6

5.27 x 10+6

206

Promethium-149

3.63 x 10+1

6.92 x 10+5

1.38 x 10+6

207

Protactinium-230

4.19 x 10-2

7.44 x 10+5

1.49 x 10+6

208

Protactinium-231

2.29 x 10-4

9.65 x 10+2

1.93 x 10+3

209

Protactinium-233

8.05 x 100

7.87 x 10+5

1.87 x 10+6

210

Radium-2231

4.32 x 10-3

6.85 x 10+3

1.37 x 10+4

211

Radium-2241

1.03 x 10-2

1.05 x 10+4

2.11 x 10+4

212

Radium-225

5.13 x 10-3

7.21 x 10+3

1.44 x 10+4

213

Radium-2261

1.86 x 10-3

2.45 x 10+3

4.89 x 10+3

214

Radium-227

1.06 x 10+2

8.15 x 10+6

1.63 x 10+7

215

Radium-2281

1.15 x 10-2

1.02 x 10+3

2.04 x 10+3

216

Radon-2201

2.25 x 10+1

-

-

217

Radon-2221

1.12 x 10+2

-

-

218

Rhenium-186

2.48 x 10+1

4.57 x 10+5

9.13 x 10+5

219

Rhenium-188

4.02 x 10+1

4.89 x 10+5

9.78 x 10+5

220

Rhodium-103m

1.19 x 10+4

1.80 x 10+8

3.60 x 10+8

221

Rhodium-105

6.77 x 10+1

1.85 x 10+6

3.70 x 10+6

222

Rubidium-81

4.38 x 10+2

1.27 x 10+7

2.54 x 10+7

223

Rubidium-86

2.29 x 10+1

2.45 x 10+5

4.89 x 10+5

224

Ruthenium-10

1.06 x 10+1

9.38 x 10+5

1.88 x 10+6

225

Ruthenium-105

1.19 x 10+2

2.63 x 10+6

5.27 x 10+6

226

Ruthenium-1061

4.80 x 10-1

9.78 x 10+4

1.96 x 10+5

227

Ruthenium-97

1.86 x 10+2

4.57 x 10+6

9.13 x 10+6

228

Samarium-147

3.35 x 10-3

1.40 x 10+4

2.80 x 10+4

229

Samarium-151

8.05 x 100

6.99 x 10+6

1.40 x 10+7

230

Samarium-153

4.38 x 10+1

9.26 x 10+5

1.85 x 10+6

231

Scandium-44

9.93 x 10+1

1.96 x 10+6

3.91 x 10+6

232

Scandium-46

4.65 x 100

4.57 x 10+5

9.13 x 10+5

233

Scandium-47

4.08 x 10+1

1.27 x 10+6

2.54 x 10+6

234

Scandium-48

1.86 x 10+1

4.03 x 10+5

8.06 x 10+5

235

Selenium-73

1.24 x 10+2

1.76 x 10+6

3.51 x 10+6

236

Selenium-75

1.75 x 10+1

2.63 x 10+5

5.27 x 10+5

237

Silicon-31

2.71 x 10+2

4.28 x 10+6

8.56 x 10+6

238

Silicon-32

2.71 x 10-1

1.22 x 10+6

2.45 x 10+6

239

Silver-105

3.72 x 10+1

1.46 x 10+6

2.91 x 10+6

240

Silver-108m

8.51 x 10-1

2.98 x 10+5

5.96 x 10+5

241

Silver-110m

2.48 x 100

2.45 x 10+5

4.89 x 10+5

242

Silver-111

1.75 x 10+1

5.27 x 10+5

1.05 x 10+6

243

Sodium-22

1.49 x 10+1

2.14 x 10+5

4.28 x 10+5

244

Sodium-24

5.62 x 10+1

1.59 x 10+6

3.19 x 10+6

245

Strontium-82

2.98 x 100

1.12 x 10+5

2.25 x 10+5

246

Strontium-85

3.87 x 10+1

1.22 x 10+6

2.45 x 10+6

247

Strontium-85m

4.02 x 10+3

1.12 x 10+8

2.25 x 10+8

248

Strontium-87m

8.51 x 10+2

2.08 x 10+7

4.15 x 10+7

249

Strontium-89

3.97 x 100

2.63 x 10+5

5.27 x 10+5

250

Strontium-901

1.99 x 10-1

2.45 x 10+4

4.89 x 10+4

251

Strontium-91

5.22 x 10+1

9.01 x 10+5

1.80 x 10+6

252

Strontium-92

8.76 x 10+1

1.40 x 10+6

2.80 x 10+6

253

Sulphur-35

2.29 x 10+2

8.90 x 10+5

1.78 x 10+6

254

Tantalum-182

3.07 x 100

4.57 x 10+5

9.13 x 10+5

255

Technetium-95m

3.42 x 10+1

1.10 x 10+6

2.21 x 10+6

256

Technetium-96

2.98 x 10+1

6.23 x 10+5

1.25 x 10+6

257

Technetium-96m

2.71 x 10+3

5.27 x 10+7

1.05 x 10+8

258

Technetium-97

1.42 x 10+2

8.25 x 10+6

1.65 x 10+7

259

Technetium-97m

9.61 x 100

1.04 x 10+6

2.08 x 10+6

260

Technetium-99

7.64 x 100

8.78 x 10+5

1.76 x 10+6

261

Technetium-99m

1.03 x 10+3

3.11 x 10+7

6.23 x 10+7

262

Tellurium-123m

7.64 x 100

4.89 x 10+5

9.78 x 10+5

263

Tellurium-125m

9.02 x 100

7.87 x 10+5

1.57 x 10+6

264

Tellurium-127

1.65 x 10+2

4.03 x 10+6

8.06 x 10+6

265

Tellurium-127m

4.14 x 100

2.98 x 10+5

5.96 x 10+5

266

Tellurium-129

5.22 x 10+2

1.09 x 10+7

2.17 x 10+7

267

Tellurium-129m

4.73 x 100

2.28 x 10+5

4.57 x 10+5

268

Tellurium-131

4.88 x 10+2

7.87 x 10+6

1.57 x 10+7

269

Tellurium-131m

1.86 x 10+1

3.60 x 10+5

7.21 x 10+5

270

Tellurium-132

9.93 x 100

1.85 x 10+5

3.70 x 10+5

271

Tellurium-133

6.77 x 10+2

9.51 x 10+6

1.90 x 10+7

272

Tellurium-133m

1.57 x 10+2

2.45 x 10+6

4.89 x 10+6

273

Tellurium-134

2.71 x 10+2

6.23 x 10+6

1.25 x 10+7

274

Terbium-160

4.51 x 100

4.28 x 10+5

8.56 x 10+5

275

Thallium-200

1.19 x 10+2

3.42 x 10+6

6.85 x 10+6

276

Thallium-201

3.92 x 10+2

7.21 x 10+6

1.44 x 10+7

277

Thallium-202

9.61 x 10+1

1.52 x 10+6

3.04 x 10+6

278

Thallium-204

4.80 x 10+1

5.27 x 10+5

1.05 x 10+6

279

Thorium-2261

3.82 x 10-1

1.90 x 10+6

3.81 x 10+6

280

Thorium-227

3.10 x 10-3

7.70 x 10+4

1.54 x 10+5

281

Thorium-2281

7.64 x 10-4

9.78 x 10+3

1.96 x 10+4

282

Thorium-2291

3.01 x 10-4

1.43 x 10+3

2.85 x 10+3

283

Thorium-230

7.44 x 10-4

3.26 x 10+3

6.52 x 10+3

284

Thorium-231

7.44 x 10+1

2.01 x 10+6

4.03 x 10+6

285

Thorium-2341

4.08 x 100

2.01 x 10+5

4.03 x 10+5

286

Thorium-nat including thorium-232

7.09 x 10-4

3.11 x 10+3

6.23 x 10+3

287

Thulium-170

4.51 x 100

5.27 x 10+5

1.05 x 10+6

288

Thulium-171

2.29 x 10+1

6.23 x 10+6

1.25 x 10+7

289

Tin-113

1.19 x 10+1

9.38 x 10+5

1.88 x 10+6

290

Tin-117m

1.29 x 10+1

9.65 x 10+5

1.93 x 10+6

291

Tin-12

1.06 x 10+2

2.98 x 10+6

5.96 x 10+6

292

Tin-125

9.93 x 100

2.21 x 10+5

4.42 x 10+5

293

Tungsten-181

6.93 x 10+2

8.35 x 10+6

1.67 x 10+7

294

Tungsten-185

1.35 x 10+2

1.37 x 10+6

2.74 x 10+6

295

Tungsten-187

9.02 x 10+1

9.65 x 10+5

1.93 x 10+6

296

Tungsten-188

3.55 x 10+1

2.98 x 10+5

5.96 x 10+5

297

Uranium-2301

1.99 x 10-3

1.25 x 10+4

2.49 x 10+4

298

Uranium-231

7.44 x 10+1

2.45 x 10+6

4.89 x 10+6

299

Uranium-2321

8.51 x 10-4

2.08 x 10+3

4.15 x 10+3

300

Uranium-233

3.42 x 10-3

1.37 x 10+4

2.74 x 10+4

301

Uranium-234

3.50 x 10-3

1.40 x 10+4

2.80 x 10+4

302

Uranium-2351

3.87 x 10-3

1.49 x 10+4

2.98 x 10+4

303

Uranium-236

3.77 x 10-3

1.49 x 10+4

2.98 x 10+4

304

Uranium-237

1.65 x 10+1

8.90 x 10+5

1.78 x 10+6

305

Uranium-238

4.08 x 10-3

1.56 x 10+4

3.11 x 10+4

306

Uranium-239

8.51 x 10+2

2.45 x 10+7

4.89 x 10+7

307

Uranium-240

3.55 x 10+1

6.23 x 10+5

1.25 x 10+6

308

Uranium-nat

4.08 x 10-3

1.56 x 10+4

3.11 x 10+4

309

Vanadium-48

1.10 x 10+1

3.42 x 10+5

6.85 x 10+5

310

Xenon-131m

4.28 x 10+4

-

-

311

Xenon-133

1.14 x 10+4

-

-

312

Xenon-135

1.43 x 10+3

-

-

313

Ytterbium-169

1.06 x 10+1

9.65 x 10+5

1.93 x 10+6

314

Ytterbium-175

4.25 x 10+1

1.56 x 10+6

3.11 x 10+6

315

Yttrium-88

7.26 x 100

5.27 x 10+5

1.05 x 10+6

316

Yttrium-90

1.75 x 10+1

2.54 x 10+5

5.07 x 10+5

317

Yttrium-91

3.55 x 100

2.85 x 10+5

5.71 x 10+5

318

Yttrium-91m

1.99 x 10+3

6.23 x 10+7

1.25 x 10+8

319

Yttrium-92

1.06 x 10+2

1.40 x 10+6

2.80 x 10+6

320

Yttrium-93

4.96 x 10+1

5.71 x 10+5

1.14 x 10+6

321

Zinc-65

1.03 x 10+1

1.76 x 10+5

3.51 x 10+5

322

Zinc-69

6.93 x 10+2

2.21 x 10+7

4.42 x 10+7

323

Zinc-69m

9.02 x 10+1

2.08 x 10+6

4.15 x 10+6

324

Zirconium-931

1.03 x 100

2.45 x 10+6

4.89 x 10+6

325

Zirconium-95

5.41 x 100

7.78 x 10+5

1.56 x 10+6

326

Zirconium-971

2.13 x 10+1

3.26 x 10+5

6.52 x 10+5

The superscript ‘1’ immediately following an item in column 1 indicates that the item’s concentration is the concentration of the parent radionuclide and its progeny when in secular equilibrium.

sch 3 amd 2012 SL No. 246 s 10

Schedule 4 Proof of identity documents

section 10

Part 1 Primary identity documents

1Australian birth certificate
2overseas birth certificate accompanied by a passport or Australian visa document issued by the Commonwealth Department of Immigration and Citizenship
3document of identity recognised by the Commonwealth Department of Immigration and Citizenship
4Australian passport that is current or has not been expired for more than 2 years
5current foreign passport
6document evidencing Australian citizenship issued by the Commonwealth Department of Immigration and Citizenship
7Australian driver’s licence that is current or has not been expired for more than 2 years

Part 2 Secondary identity documents

1current identification card issued by the Commonwealth or a State as evidence of the person’s entitlement to a financial benefit

Example—

1seniors health card
2health care card
3Medicare card
4pensioner concession card
5entitlement card issued by the Department of Veteran’s Affairs
2current account card or credit card, issued by a financial institution, that contains the person’s name and signature
3account statement issued by a financial institution within the previous year
4document evidencing discharge from military service within the previous 2 years
5student identification card containing the person’s photograph and signature that is current or has not been expired for more than 2 years
6document evidencing enrolment in an education institution within the previous 2 years
7document evidencing electoral enrolment within the previous 2 years
8utilities account statement issued by a utilities provider within the previous year
9notice of land valuation, water rates or council rates issued within the previous year

Schedule 5 Qualifications

section 50

Column 1

Column 2

Radiation practice

Qualification

intra-oral, or extra-oral, dental diagnostic radiography of a person or dental therapeutic procedures carried out with a laser apparatus

general registration under the Health Practitioner Regulation National Law as a dentist

plain film diagnostic radiography of a person

general registration under the Health Practitioner Regulation National Law as a medical practitioner

plain film diagnostic radiography of the spine, pelvis or extremities of a person

general registration under the Health Practitioner Regulation National Law as a chiropractor

plain film diagnostic radiography of an animal

registration under the Veterinary Surgeons Act 1936

sch 5 amd 2012 SL No. 246 s 11

Schedule 6 Authorised persons

section 63

Part 1 Diagnostic procedures

 

Column 1

Column 2

 

Diagnostic procedure

Authorised person

1

intra-oral and extra-oral dental diagnostic radiography of the teeth and facial bones

a dentist or oral health therapist

2

intra-oral bitewing dental diagnostic radiography

a dental therapist if the intra-oral bitewing dental radiography is to be performed under a protocol for intra-oral bitewing dental radiography approved by the chief executive

3

plain film diagnostic radiography

a person who is—

(a)  a medical practitioner; or
  

(b)  a nurse practitioner; or
  

(c)  a registered nurse; or
  

(d)  a physiotherapist

4

plain film diagnostic radiography of the hand and wrist or lateral plain film diagnostic radiography projections of the cervical spine

a dentist

5

plain film diagnostic radiography of the foot, ankle, lower leg, knee, thigh and hip

a person registered under the Health Practitioner Regulation National Law to practise in the podiatry profession, other than as a student

6

plain film diagnostic radiography of the neuromusculoskeletal system

a chiropractor

7

plain film diagnostic radiography of the chest

the chief executive, for screening for tuberculosis, under a protocol for tuberculosis screening approved by the chief executive, of a person who presents at a public sector health service facility which undertakes screening procedures for tuberculosis

8

mammography

the chief executive, for mammography, under a protocol for breast cancer screening approved by the chief executive, of a woman who—

(a)  presents at a BreastScreen Queensland Service for the purpose of breast cancer screening; and
  

(b)  is eligible to participate in the Queensland Health BreastScreen Queensland Program; and
  

(c)  signs the “BreastScreen Queensland Consent for Screening Mammogram” form

9

computed tomography, and mammography

a person who is—

(a)  a specialist health practitioner in the specialty of radiology—diagnostic radiology; or
  

(b)  a medical practitioner undergoing a period of training in the specialty of radiology—diagnostic radiology

10

computed tomography, mammography and bone mineral densitometry

a person who is either of the following if the computed tomography, mammography or bone mineral densitometry is part of a radiation oncology procedure—

(a)  a specialist health practitioner in the specialty of radiation oncology;
  

(b)  a medical practitioner undergoing a period of training in the specialty of radiation oncology

11

fluoroscopy

a person who is—

(a)  a specialist health practitioner in a recognised specialty; or
  

(b)  a medical practitioner undergoing a period of training in a recognised specialty

12

bone mineral densitometry

a person who is—

(a)  a specialist health practitioner in the specialty of—
  

  
(i)  radiology—diagnostic radiology; or
  

  
(ii)  radiology—nuclear medicine; or
  

  
(iii)  physician—endocrinology; or
  

  
(iv)  physician—nuclear medicine; or
  

(b)  a medical practitioner undergoing a period of training in a specialty mentioned in paragraph (a); or
  

(c)  the holder of a written approval from the chief executive stating the person is competent to carry out the procedure, and who is—
  

  
(i)  a specialist health practitioner in a specialty other than a specialty mentioned in paragraph (a); or
  

  
(ii)  a medical practitioner undergoing a period of training in a specialty other than a specialty mentioned in paragraph (a)

13

diagnostic nuclear medicine

a person who is—

(a)  a specialist health practitioner in the specialty of radiology—nuclear medicine; or
  

(b)  a medical practitioner undergoing a period of training in the specialty of radiology—nuclear medicine; or
  

(c)  a specialist health practitioner in the specialty of physician—nuclear medicine; or
  

(d)  a medical practitioner undergoing a period of training in the specialty of physician—nuclear medicine

14

in vivo tests for pathology involving the use of unsealed radioactive substances

a person who is—

(a)  a specialist health practitioner in the specialty of pathology; or
(b)  a medical practitioner undergoing a period of training in the specialty of pathology

Part 2 Therapeutic procedures

 

Column 1

Column 2

 

Therapeutic procedure

Authorised person

16

treatment of malignant and benign conditions involving the use of radiation sources

a person who is—

(a)  a specialist health practitioner in the specialty of radiation oncology; or
(b)  a medical practitioner undergoing a period of training in the specialty of radiation oncology

17

treatment of malignant and benign conditions involving the use of unsealed radioactive substances

a person who is—

(a)  a specialist health practitioner in the specialty of radiology—nuclear medicine; or
(b)  a medical practitioner undergoing a period of training in the specialty of radiology—nuclear medicine; or
(c)  a specialist health practitioner in the specialty of physician—nuclear medicine; or
(d)  a medical practitioner undergoing a period of training in the specialty of physician—nuclear medicine

18

treatment of skin lesions involving the use of sealed radioactive substances

a person—

(a)  who is—

(i)  a specialist health practitioner in the specialty of dermatology; or
(ii)  a medical practitioner undergoing a period of training in the specialty of dermatology; and

  

(b)  whose decision to prescribe the procedure is in accordance with a decision, about the desired outcome of the treatment, made by the person and another person who is a specialist health practitioner in the specialty of radiation oncology

19

treatment of eye lesions involving the use of sealed radioactive substances

a person who is—

(a)  a specialist health practitioner in the specialty of ophthalmology; or
(b)  a medical practitioner undergoing a period of training in the specialty of ophthalmology

20

treatment of vascular stenosis

a person—

(a)  who is—
  

(i)  a specialist health practitioner in the specialty of—

(A)  physician—cardiology; or
(B)  surgery—vascular surgery; or
(C)  radiology—diagnostic radiology; or

  

(ii)  a medical practitioner undergoing a period of training in the specialty of—

(A)  physician—cardiology; or
(B)  surgery—vascular surgery; or
(C)  radiology—diagnostic radiology; and

  

(b)  whose decision to prescribe the procedure is in accordance with a decision about the desired outcome of the treatment, made by the person and another person—
  

(i)  who is a specialist health practitioner in the specialty of radiology—nuclear medicine and holds a written approval from the chief executive stating the person is competent to carry out the procedure; or
  

(ii)  who is a specialist health practitioner in the specialty of radiation oncology; or
  

(iii)  who is a specialist health practitioner in the specialty of physician—nuclear medicine

21

therapeutic procedures involving the use of laser apparatus

a person who is—

(a)  a medical practitioner; or
(b)  a dentist

sch 6 amd 2014 SL No. 81 s 14; 2016 SL No. 17 s 44

Schedule 7 Training

section 67

1course entitled ‘Compliance testing of diagnostic imaging equipment training course’ conducted by the department
2course entitled ‘Laser concepts in health care’ conducted by the Australian Centre for Medical Laser Technology Inc.

Schedule 8 Fees

sections 87, 88 and 89

Part 1 Possession licences

Division 1 Possession licences for radioactive substances

$

1

Application fee for a possession licence—

(a)  if the radioactive substance is a security enhanced source

968.50

(b)  otherwise

484.00

2

Licence fee for a possession licence for the possession of a radioactive substance for a radiation practice—

(a)  if the term of the licence is 1 year or less
 

  
(i)  base fee

276.00

  
(ii)  for each sealed radioactive substance or type of unsealed radioactive substance

110.50

(b)  if the term of the licence is more than 1 year but not more than 2 years—

  
(i)  base fee

552.00

  
(ii)  for each sealed radioactive substance or type of unsealed radioactive substance

221.00

(c)  if the term of the licence is more than 2 years but not more than 3 years—

  
(i)  base fee

828.00

  
(ii)  for each sealed radioactive substance or type of unsealed radioactive substance

331.50

Division 2 Possession licences for radiation apparatus

$

3

Application fee for a possession licence for the possession of a radiation apparatus for a radiation practice

484.00

4

Licence fee for a possession licence for the possession of a radiation apparatus for a radiation practice—

(a)  if the term of the licence is 1 year or less—

  
(i)  base fee

276.00

  
(ii)  for each radiation apparatus

82.50

(b)  if the term of the licence is more than 1 year but not more than 2 years—

  
(i)  base fee

552.00

  
(ii)  for each radiation apparatus

165.00

(c)  if the term of the licence is more than 2 years but not more than 3 years—

  
(i)  base fee

828.00

  
(ii)  for each radiation apparatus

247.50

Part 2 Transport licences and use licences

$

5

Application fee for a transport licence or use licence

96.50

6

Licence fee for a transport licence or use licence—

(a)  if the term of the licence is 1 year or less

69.00

(b)  if the term of the licence is more than 1 year but not more than 2 years

138.00

(c)  if the term of the licence is more than 2 years but not more than 3 years

207.00

Part 3 Other Act instruments

$

7

Application fee for an approval to acquire

41.50

8

Application fee for an approval to dispose

484.00

9

Application fee for an approval to relocate

28.00

10

Application fee for an accreditation certificate

276.00

11

Accreditation certificate fee—

(a)  if the term of the certificate is 1 year or less

138.00

(b)  if the term of the certificate is more than 1 year but not more than 2 years

276.00

(c)  if the term of the certificate is more than 2 years but not more than 3 years

414.00

12

Application fee for a radiation safety officer certificate

96.50

13

Radiation safety officer certificate fee—

(a)  if the term of the certificate is 1 year or less

69.00

(b)  if the term of the certificate is more than 1 year but not more than 2 years

138.00

(c)  if the term of the certificate is more than 2 years but not more than 3 years

207.00

Part 4 Other fees

$

14

Application by a possession licensee to change the licensee’s approved radiation safety and protection plan for a radiation practice (Act, s 31(2)(b))

484.00

15

Application by a possession licensee to change the licensee’s approved security plan (Act, s 34D(2)(b))

484.00

16

Application for approval of a transport security plan (Act, s 34J(1)(c)(iii))

484.00

17

Application by a transport security plan holder to change the holder’s approved transport security plan (Act, s 34O(2)(b))

484.00

18

Application by the holder of a conditional Act instrument to change the conditions of the instrument imposed by the chief executive (Act, s 96(2)(b))

484.00

19

Issue of an Act instrument to replace a lost, stolen, destroyed or damaged Act instrument (Act, s 101(4))

28.00

20

Security check and criminal history check (Act, s 103A(3))

114.50

21

Copy of the register, or a part of it, for each page (Act, s 208(c))

1.00

sch 8 sub 2011 SL No. 117 s 16; 2012 SL No. 152 s 15; 2013 SL No. 185 s 14; 2014 SL No. 211 s 16; 2015 SL No. 49 s 16; 2016 SL No. 90 s 12; 2017 SL No. 81 s 17; 2018 SL No. 62 s 16; 2019 SL No. 98 s 16

Schedule 9 Dictionary

section 3

administrative security actions means administrative procedures, security checks, assessments and other measures to deal with risks to the security of a security enhanced source at different threat levels.
ancillary imaging equipment, used in connection with the use of a radiation source to carry out a radiation practice involving the production of images, means equipment, other than the source, used in the production and viewing of the images.
ARPANSA means the Australian Radiation Protection and Nuclear Safety Agency.
AS/NZS means an Australian/New Zealand Standard jointly published by Standards Australia and Standards New Zealand.
Bq means a becquerel.
cabinet radiation apparatus means an ionising radiation apparatus—
(a)contained in a cabinet that is shielded in a way that minimises the transmission of ionising radiation through the shielding; and
(b)used for the radiographic, or fluoroscopic, imaging of—
(i)things for security, or quality control, purposes; or
(ii)excised tissue for pathology purposes.
chiropractor means a person registered under the Health Practitioner Regulation National Law to practise in the chiropractic profession, other than as a student.
commissioning means the tasks involved in installing a radiation source, including tasks to ensure the source is operating in the way it is designed to operate.
dental therapist means a person registered under the Health Practitioner Regulation National Law—
(a)to practise in the dental profession, other than as a student; and
(b)in the dental therapists division of that profession.
dentist means a person registered under the Health Practitioner Regulation National Law—
(a)to practise in the dental profession, other than as a student; and
(b)in the dentists division of that profession.
diagnostic radiography protocol means a document certified by the chief executive and published by the department stating the circumstances in which, and the conditions under which, a person who may act under the protocol may request plain film diagnostic radiography.
document of identity means any document given by a person to the Commonwealth Department of Immigration and Citizenship for the purpose of proving their identity.
educational institution means a school, university, training institution or professional college that—
(a)educates persons about radiation sources; or
(b)uses radiation sources in the course of its education of persons.
enclosed radiation apparatus means an ionising radiation apparatus—
(a)contained in a cabinet that is shielded in a way that minimises the transmission of ionising radiation through the shielding; and
(b)used for monitoring industrial processes or industrial gauging.
equivalent dose, for a person’s organ or tissue that is exposed to radiation, means the equivalent dose for the organ or tissue, calculated in accordance with the document entitled ‘Recommendations for limiting exposure to ionizing radiation (1995) (Guidance note [NOHSC:3022(1995)])’ published by ARPANSA.

Editor’s note—

The document is available on the internet or may be purchased from ARPANSA, 619 Lower Plenty Road, Yallambie, Victoria 3085.
external effective dose, received by a person, means the total of the weighted equivalent doses for all organs and tissues of the person as a result of exposure of the organs and tissues to radiation emitted from ionising radiation sources external to the person’s body.
gaseous tritium light device means equipment or an instrument, article or subassembly, other than equipment or an instrument, article or subassembly that is a timepiece, incorporating a sealed glass container—
(a)filled with the radionuclide hydrogen-3 in a gaseous form; and
(b)coated internally with a phosphor.
GBq means a gigabecquerel.
gigabecquerel means 1,000,000,000 becquerels.
health-related exposure, of a person to ionising radiation, means the exposure of the person to the radiation while undergoing a diagnostic or therapeutic procedure involving the irradiation of the person.
ICRP means the International Commission on Radiological Protection.
internal effective dose, received by a person, means the effective dose from a radionuclide inhaled, ingested or introduced into the person’s body, calculated in accordance with the document entitled ‘Dose Coefficients for Intakes of Radionuclides by Workers’, and known as ‘ICRP Publication 68’, prepared by ICRP.

Editor’s note—

The document may be purchased from Elsevier, Tower 1, Level 12, 475 Victoria Ave, Chatswood, New South Wales 2067.
kBq means a kilobecquerel.
kilobecquerel means 1,000 becquerels.
laser apparatus means a laser that is a radiation apparatus under section 7.
laser standard means AS/NZS 2211.1-2004 (Safety of laser products, Part 1: Equipment classification, requirements and user’s guide).
MBq means a megabecquerel.
megabecquerel means 1,000,000 becquerels.
microgray means 1/1,000,000 part of a gray.
millisievert means 1/1,000 part of a sievert.
mineral see the Mineral Resources Act 1989, section 6.
mineral substances see section 5(1).
mSv means a millisievert.
natural background exposure, of a person to ionising radiation, means the exposure of the person to ionising radiation occurring naturally in the environment, other than exposure to ionising radiation directly attributable to the carrying out of a radiation practice.
NHMRC means the National Health and Medical Research Council.
NRMMC means the Natural Resource Management Ministerial Council.
nuclear medicine image means an image produced as a result of the detection of the radiation emitted by a radionuclide in a person, after the person has been administered, or injected with, a radiopharmaceutical.
nurse practitioner means a person registered under the Health Practitioner Regulation National Law—
(a)to practise in the nursing profession, other than as a student; and
(b)whose registration is endorsed under that law as being qualified to practise as a nurse practitioner.

sch 9 def nurse practitioner amd 2018 SL No. 187 s 14 (1)

occupational exposure, of a person to ionising radiation, means the exposure of the person to the radiation in the course of the person’s work, other than natural background exposure to ionising radiation.
oral health therapist means a person registered under the Health Practitioner Regulation National Law—
(a)to practise in the dental profession, other than as a student; and
(b)in the oral health therapists division of that profession.
personal protective equipment means equipment that, when worn by a person while involved in carrying out a radiation practice, reduces the exposure of the person to radiation attributable to the carrying out of the practice.
physician’s assistant means a person—
(a)appointed by the chief executive, and employed by the department, as a physician’s assistant; or
(b)appointed by a Hospital and Health Service established under the Hospital and Health Boards Act 2011, and employed by the Service, as a physician’s assistant.

sch 9 def physician’s assistant sub 2012 SL No. 90 s 41 sch

physiotherapist means a person registered under the Health Practitioner Regulation National Law to practise in the physiotherapy profession, other than as a student.

sch 9 def physiotherapist ins 2014 SL No. 81 s 15

plain film diagnostic radiography includes a digital equivalent of plain film diagnostic radiography.
practice plan, for a physician’s assistant, means a document that—
(a)is developed and signed by a physician’s assistant and his or her supervising medical officer; and
(b)states the circumstances and conditions for a physician’s assistant to request a specified diagnostic procedure; and
(c)is in a form approved by the chief executive.
privately owned ...

sch 9 def privately owned om 2013 SL No. 288 8(1)

public exposure, of a person to ionising radiation, means the exposure of the person to the radiation, other than health-related exposure, natural background exposure or occupational exposure to ionising radiation.
public sector health service ...

sch 9 def public sector health service om 2012 SL No. 90 s 41 sch

public sector health service facility see the Hospital and Health Boards Act 2011, schedule 2.

sch 9 def public sector health service facility ins 2012 SL No. 90 s 41 sch

quality control procedures, for ancillary imaging equipment used in connection with the use of a radiation source to carry out a radiation practice involving the production of images, means preventative maintenance, or routine checking, procedures undertaken to ensure the correct operation of the equipment for the practice.
quality control procedures, for a radiation source used in carrying out a radiation practice, means—
(a)if the source is a radiation apparatus—preventative maintenance, or routine checking, procedures undertaken to ensure the correct operation of the apparatus for the practice; or
(b)if the source is a radioactive substance—routine checking procedures undertaken to verify the suitability of the substance for the practice.
quality control procedures, for a sealed source apparatus used in carrying out a radiation practice, means preventative maintenance, or routine checking, procedures undertaken to ensure the correct operation of the apparatus for the practice.
recognised specialty see the Health Practitioner Regulation National Law (Queensland), section 5.
registered nurse means a person registered under the Health Practitioner Regulation National Law—
(a)to practise in the nursing profession, other than as a student; and
(b)in the registered nurses division of that profession.

sch 9 def registered nurse amd 2018 SL No. 187 s 14 (2)

relevant solarium means a solarium other than a solarium owned by an individual and not used for a business.

sch 9 def relevant solarium amd 2013 SL No. 288 s 8 (2)

security enhanced source see section 8.
SI means the International System of Units.
sievert, for a total effective or equivalent dose, means the SI unit for the dose.
skin photo type means a classification of skin using the Fitzpatrick scale of skin photo typing.
solarium means an electrically powered apparatus designed to produce tanning of human skin by exposure of the skin to non-ionising radiation emitted by the apparatus.
specialist health practitioner, in a specialty, means a person registered under the Health Practitioner Regulation National Law to practise in the medical profession as a specialist registrant in the specialty.
supervising medical officer, for a physician’s assistant, means a person who—
(a)is a medical practitioner; and
(b)supervises the work performed by the physician’s assistant in his or her employment with the department or a Hospital and Health Service established under the Hospital and Health Boards Act 2011.

sch 9 def supervising medical officer amd 2012 SL No. 90 s 41 sch

TCLP means the toxicity characteristics leaching procedure stated in AS 4439.2-1997 (Wastes, sediments and contaminated soils, Part 2: Preparation of leachates—Zero headspace procedure).
threat level see section 34.
total effective dose, for a person for a period, means the total of the external, and internal, effective doses received by the person during the period.
transport code of practice means the Code for the Safe Transport of Radioactive Material (2014) published by ARPANSA.

sch 9 def transport code of practice sub 2019 SL No. 40 s 17

veterinary surgeon see the Veterinary Surgeons Act 1936, schedule.
weighted equivalent dose, for a person’s organ or tissue that is exposed to radiation, means the product of—
(a)the tissue weighting factor for the organ or tissue stated in table 2 of the document entitled ‘Recommendations for limiting exposure to ionizing radiation (1995) (Guidance note [NOHSC:3022(1995)])’ published by ARPANSA; and
(b)the equivalent dose for the organ or tissue.